Suggestions

Chlorine dioxide system Bello Zon CDLb H2SO4

8 – 89 g/h chlorine dioxide generation

Bello Zon CDLb H2SO4 especially for applications critical with regard to corrosion for the production of low-chloride chlorine dioxide liquid. With the chlorine dioxide system, ClO2 is produced discontinuously following the acid / chlorite procedure.

Product description

Gentle disinfection without corrosion

The system produces an extremely low-chloride chlorine dioxide solution from sodium chlorite and sulphuric acid instead of hydrochloric acid. Batch production is an extremely safe, managed process. The low-chloride CDLb solution is suited to disinfection applications in sensitive stainless steel environments such as tunnel pasteurisers, autoclaves, cooling circuits, belt-based lubrication systems.

The chlorine dioxide is buffered in an integrated or external buffer tank at a concentration of 1500 mg/l.

The broad product range of metering pumps and control variants can be used to run several points of injection with chlorine dioxide from one buffer tank.

The closed gas circuit prevents chlorine dioxide from being able to escape from the system, guaranteeing economical and environmentally friendly operation with minimal use of chemicals.

Features and Benefits

  • Very little potential for corrosion due to the low chloride concentration
  • Ideal specifically for circulation systems
  • Simple way to provide several points of injection
  • Outstanding operating safety and reliability thanks to intrinsically safe process control
  • System monitoring in real time from any location via DULCONNEX Platform: improved process reliability, overall reliability and transparency through real-time monitoring, individual alarms and automated reports

Technical Details

  • Power supply: 100-230 V, 50/60 Hz
  • Inputs: 2 freely configurable digital inputs for the Pause, High metering, Intermittent metering or Manual metering functions as well as an external common alarm, 4 digital inputs for monitoring the chemical supply (warning / empty message), 1 digital input for contact water meter 0.25 - 20 Hz, 1 frequency input for water meter 10 - 10,000 Hz
  • Outputs: 1 operating signal relay, 1 alarm signal relay, 1 warning signal relay, 1 +5 V voltage output as supply voltage for water meter with Hall sensor
  • Operating substances: 7.5% sodium chlorite, purity in accordance with EN 938, 25 % sulfuric acid, purity in accordance with EN 939, potable water
  • Degree of protection: IP 65

Technical Data

Type

Generation capacity

Operating temperature

Concentration

Minimum metering rate

Dimensions H x W x D

Weight

lb/h | g/h

°F (°C)

mg/l

gph | l/h

inch

lb | kg

CDLb 08 H2SO4

0.02 | 8

50…104 (10…40)

1,500

2.1 | 8

48.7 x 34.6 x 12

92.6 | 42

CDLb 16 H2SO4

0.04 | 16

50…104 (10…40)

1,500

3.4 | 13

48.7 x 34.6 x 12

101.4 | 46

CDLb 41 H2SO4

0.09 | 41

50…104 (10…40)

1,500

7.9 | 30

61 x 31.5 x 13.6

161 | 73

CDLb 89 H2SO4

0.2 | 89

50…104 (10…40)

1,500

-

51.2 x 34.6 x 16.7

121 | 55

Interfaces

Type CDLb H2SO4 8 g/h16 g/h41 g/h89 g/h 
Water inletProMinent/Neutral12-912-912-9Di20/DN15 
 SwitzerlandDi20/DN15Di20/DN15Di20/DN15Di20/DN15 
Connector dimensions of metering pump for acid and chlorite 6x46x46x46x4 
ClO2 outputwith internal storage/pump/back pressure valve6-412-912-9  
 with internal storage/pump6-412-912-9  
 with internal storage, without pump6-412-912-9  
 with external storage, without pump (reactor outlet)12-912-912-9Di25/DN20 
 external storage (suction lance connector)Di25/DN20Di25/DN20Di25/DN20Di25/DN20 

Downloads for Chlorine dioxide system Bello Zon CDLb H2SO4

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by Document type
Load more matches ...
No more matches available!

Unfortunately, we did not find an appropriate match.

All words written correctly?
Search again with fewer or different search terms?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

Gentle disinfection without corrosion

The system produces an extremely low-chloride chlorine dioxide solution from sodium chlorite and sulphuric acid instead of hydrochloric acid. Batch production is an extremely safe, managed process. The low-chloride CDLb solution is suited to disinfection applications in sensitive stainless steel environments such as tunnel pasteurisers, autoclaves, cooling circuits, belt-based lubrication systems.

The chlorine dioxide is buffered in an integrated or external buffer tank at a concentration of 1500 mg/l.

The broad product range of metering pumps and control variants can be used to run several points of injection with chlorine dioxide from one buffer tank.

The closed gas circuit prevents chlorine dioxide from being able to escape from the system, guaranteeing economical and environmentally friendly operation with minimal use of chemicals.

Features and Benefits

  • Very little potential for corrosion due to the low chloride concentration
  • Ideal specifically for circulation systems
  • Simple way to provide several points of injection
  • Outstanding operating safety and reliability thanks to intrinsically safe process control
  • System monitoring in real time from any location via DULCONNEX Platform: improved process reliability, overall reliability and transparency through real-time monitoring, individual alarms and automated reports

Application

Technical Data

Downloads

Find local ProMinent representative

Contact us

»We are looking forward to your enquiry.«

+1 412-787-2484 

Matching Products

The DULCOMETER Type D1Cb is suitable for applications in drinking water, wastewater, and cooling water treatment. The single channel measuring and control unit D1Cb is equipped for all-important measured variables for basic applications in water treatment and with an error and calibration logbook.

more

The DULCOMETER DACb controller uses intelligent controller functions to close the control circuit between ProMinent DULCOTEST sensors and ProMinent metering pumps.

more

PE storage tanks produced in a rotation process. ProMinent metering pumps, suction lances and stirrers can all be added. The stackable PE collecting pans are available in matching sizes.

more

The DULCONNEX Gateway safely and reliably transfers the data of all products supported as standard to the DULCONNEX Cloud

more

ORP measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real time. Can be used in water treatment or industrial process waters with strict requirements.

more

Chlorine dioxide measurement with DULCOTEST sensors offers precise, reliable, application-specific measured values in real time for all oxidation and disinfection tasks.

more

Chlorite measurements with DULCOTEST sensors in disinfection processes involving chlorine dioxide – high process reliability guaranteed.

more