Ultromat® Continuous Flow Systems
In Continuous Flow Systems, the reservoir is separated into multiple chambers. Thus, it is extremely unlikely that recently mixed polymer gets into the suction area of the metering pump (product entrainment). This helps to make sure that the efficiency of the subsequent drainage generator is conserved in its entirety.
Advantages- Low product entrainment
- High operation comfort
- Easy commissioning
- Low space requirement
- Low product entrainment
- High operation comfort
- Easy commissioning
- Low space requirement
Features
- Issue quantity 106 to 2,113 gph (400 - 8,000 L/h)
- Maturing time at maximum issue quantity ca. 60 minutes
- Control with integrated operation panel and display
- Exact observation of the solution concentration through proportional control
Operation Safety
- Water supply with continuous water pressure > 72.5 psig (5 bar)
Plant Types
- AT/96: Three chamber continuous flow system for powdery flocculant
- ATF/96: Three chamber continuous flow system for powdery and fluid flocculant
- AF/96: Two chamber continuous flow system for fluid flocculant
Technical Data
| AT 400/96 ATF 400/96 AF 400/96 | AT 1000/96 ATF 1000/96 AF 1000/96 | AT 2000/96 ATF 2000/96 AF 2000/96 | AT 4000/96 ATF 4000/96 AF 4000/96 | AT 8000/96 ATF 8000/96 AF 8000/96 |
| Reservoir capacity (US gal.) | 106 | 264 | 528 | 1,057 | 2,113 |
| Reservoir capacity (L) | 400 | 1,000 | 2,000 | 4,000 | 8,000 |
| Issue quantity (US gph) | 106 | 264 | 528 | 1,057 | 2,113 |
| Issue quantity (L/h) | 400 | 1,000 | 2,000 | 4,000 | 8,000 |
| Maturing time | 60 min | 60 min | 60 min | 60 min | 60 min |
Concentration | 0.05 - 0.5 % | 0.05 - 0.5 % | 0.05 - 0.5 % | 0.05 - 0.5 % | 0.05 - 0.5 % |