Previous Article Return to overview
DULCOMETER® DMT 2-Wire-Transmitters

DULCOMETER® DMT 2-Wire-Transmitters

DULCOMETER® transmitters type DMT are compact 2-wire-transmitters for the measuring variable pH, Redox, Chlorine, conductive conductivity and temperature. They can easily be combined with programmable logic controllers. Units can be wall or panel mounted for installation flexibility.

Advantages

  • Easily applied to many applications: pH, Redox, conductivity, Chlorine, temperature
  • Easy to use and clear menus with large graphic display in 5 languages
  • Large, easily readable graphic display for measuring values, correction values and information
  • High operation safety: probe monitoring (pH) and electrical isolation
  • Simple flexible installation
  • Automatic buffer recognition (pH)
  • Autoranging (conductivity, no measurement range shift)
  • Compact design
  • Switch between pH, Redox and temperature
  • Automatic recognition of platinum thermometer (Pt 100/Pt 1000)
  • Measuring value simulation mode for test purposes
  • Bus interface (PROFIBUS®-DP) 

Application Areas

  • Process control in chemical and pharmaceutical industries
  • Water treatment
  • Effluent water treatment
  • Power stations

Features

  • Measuring variables: pH, Redox, conductivity, Chlorine, temperature
  • High measuring safety thanks to symmetric input for pH and Redox
  • Residual current: 23 mA
  • Display of  sensor impedance for pH and Redox
  • Mounting to pillars, pipes, wall and panel mounting
  • Communication interface PROFIBUS®-DP

Technical Data

Parameter Measuring and Control Range Resolution Sensor input                    
pH -1.00...15.00
0.01 pH Input resistance > 5 x 1011
Redox -1,200...+1,200 mV
1 mV  Input resistance > 5 x 1011
Chlorine 0.01 - 5.00 ppm
0.1 - 50.00 ppm
0.01ppm

Clamp (DMT Chlorine sensors with 5-pole control cable)

Temperature -4 ...302 °F (-20...+150 °C)

32 °F

(0.1 °C)

Clamp Pt 100 / Pt 1000
Conductive Conductivity 1 µS/cm - 200 mS/cm (autoranging) 0.01µS/cm Clamp (2- or 4 electrodes measuring cells) 

Parameter Value
Accuracy 0.5 % of measuring range
Correction variable Temperature over Pt 100 or Pt 1000 (Self recognition)
Correction range

pH: 32...212 °F (0...100°C)

Conductivity: 32...212 °F (0...100°C)

(unidimensional temperature compensation)

Chlorine: 41 ... 113 °F (5...45 °C)

Cell constant at conductivity 0.002 ... 4.7"  (0.006...12.0/cm)
Feed voltage

2-wire-transmitter: 16...40 V DC, nominal 24V DC

Profibus-DP: 16...30 V DC, nominal 24 V DC

Protection class

Wall mounted: IP 65

Control panel version: IP 54

Ambient temperature

Wall mounted: 23 ...131 °F (-5...55 °C not precipitating)

Control panel version: 23 ...131 °F (-5...55 °C not precipitating)

Dimensions  (HxWxD)

Wall mounted: 4.29" x 5.31" x 2.95" (125 x 135 x 75 mm)

Control panel version: 4.29" x 5.31" x 1.18" (125 x 135 x 30 mm)

Weight in oz. (g) 15.9 (450)

ProMinent offers DULCOMETER® measurement and control devices, DULCOTEST® sensor technology as well as ProMinent metering pumps for the creation of complete control circuits. Measuring, Control, Metering and Recording, all from one hand and optimally inter-adjusted.