Next article Return to overview
DULCOMETER® D1C Single Channel Controller

DULCOMETER® D1C Single Channel Controller

The single channel controller DULCOMETER® D1C is a measurement and control device based on microprocessor technology that provides highest process safety with a comprehensive application spectrum. The controller is configurable and can thus be configured individually to meet your requirements. This is not only valid for the control parameter but also for its construction type (wall mounting or panel mounting) and many more parameters. You select what you need for your regulation task and only pay for that.

Advantages

  • Universally compatible, as many measuring values controllable: beside pH, Redox, conductivity and Chlorine, also Dissolved Oxygen, Fluoride, Bromine, Chlorine Dioxide, Chlorite, Ozone, Hydrogen Peroxyde and Peracetic Acid.
  • Easily configured to adjust to process requirements
  • Seamless integration into your process: various installation possibilities for the sensors and large number of control possibilities for metering devices.
  • Optimized process flows through special functions such as disturbance feedforward, pH compensation for Chlorine, base load metering and many limit value functions.
  • Safety: limit value monitoring with standardized metering time restrictions.
  • Easy and clear user guidance with text indicator on big graphic display in 16 languages.
  • Large,  easily readable graphic display for measuring values, correction values and information.

Features

  • Limit value control with standardized control variable shutoff
  • Disturbance insensitive probe connection in dual wire technology
  • 2 signal outputs 0/4 - 20 mA galvanically separated
  • Various construction types for wall and panel mounting
  • 1 digital input for "break" and "error" measuring water
  • Disturbance signal processing as digital or analog signal
  • 2 timers as cleaning contact or for shock metering
  • Additive basic load metering
  • Bidirectional control
  • Neutral zone control
  • Temperature compensation for pH, conductivity and Chlorine Dioxide process measuring
  • pH correction for Chlorine
  • Adjustable access code

Technical Data

Parameter Value
Accuracy 0.5 % of measuring range
Correction variable Temperature over Pt 100 or transmitter 4...20 mA

Correction range (° F)

32...212° F (0....100° C)
Disturbance signals Adder/multiplier
Control characteristic P, PI, PD, PID
Control

Bidirectional control

Dead zone control

Additive basic load

manually adjusted control variable for test purposes

Control output

2 reed contacts (pulse rate output)

2 power relays (pulse length) or

1 output for servomotor with report function

2 analogue outputs (0/4...20 mA)

Analog output

2 analog outputs (0/4...20 mA) galvanically separated, max. load 600 Ω (2nd output 400 Ω). Adjustable direction measurement, correction and control variable.

Alarm relay 250V ~3 A, 700 VA, changeover contact
Power supply 24 V AC/DC / 100 V~ / 115 V~ / 200 V~ /230 V~ ±10 %
Protection class

Wall mounted: IP 65

Control panel version: IP 54

Ambient temperature

Wall mounted: 23...104° F (-5...40° C not precipitating)

Control panel version: 32... 104° F (0...40 ° C not precipitating)

Dimensions(HxWxD)

Control panel version: 3.78" x 3.78" x 5.50" (96 x 96 x 140 mm)

Wall mounted: 7.44" x 7.87" x 3.00" (189 x 200 x 76 mm)

Parameter

Measuring and Control Range Resolution Sensor input
pH 0 - 14 0.01pH Input resistance > 1012 W
Clamp standard signal 0/4...20 mA
Redox -1,000 - +1,000 mV 1 mV

Input resistance > 5 x 10 11 W 
Clamp standard signal 0/4...20 mA

Chlorine

0.005 - 0.500 ppm
0.05 - 2.00 ppm
0.05 - 5.00 ppm
0.05 - 10.00 ppm
0.05 - 20.00 ppm
0.05 - 50.00 ppm
0.05 - 100.00 ppm

0.001 ppm
0.01 ppm

Clamp standard signal 0/4...20 mA

 

Bromine 0.02 - 2.00 ppm
0.1 - 10.0 ppm
0.01 ppm Clamp standard signal 0/4...20 mA
Conductive conductivity 0 - 20 µS/cm
0 - 200 µS/cm
0 - 2 mS/cm
0 - 200 mS/cm
0.001 µS/cm Clamp conductive conductivity
Inductive conductivity

0 - 200 µS/cm
0 - 2 mS/cm
0 - 200 mS/cm
0 - 2,000 mS/cm

0.01 µS/cm Clamp inductive conductivity
Chlorine dioxide

0.005 - 0.500 ppm
0.05 - 2.00 ppm
0.05 - 10.00 ppm
0.05 - 20.00 ppm

0.001 ppm        0.01 ppm Clamp standard signal 0/4...20 mA
Chlorite

0.005 - 0.500 ppm
0.05 - 2.00 ppm

0.001 ppm        0.01 pmm Clamp standard signal 0/4...20 mA
Ozone 0.05 - 2 ppm 0.01 ppm Clamp standard signal 0/4...20 mA
Fluoride 0.05 - 10 mg/L 0.01 ppm Clamp standard signal 0/4...20 mA
Dissolved oxygen 0.1 - 10 mg/L                                      0.1 - 20 mg/L 0.001 ppm             0.01 ppm Clamp standard signal 0/4...20 mA

Hydrogen peroxide

1 - 20 ppm
20 - 200 ppm
20 - 2,000 ppm

0.01 ppm Clamp standard signal 0/4...20 mA
Peracetic acid

1 - 20 ppm
20 - 200 ppm
20 - 2,000 ppm

0.01 ppm Clamp standard signal 0/4...20 mA
Temperature

32 - 212 °F

(0 - 100 °C)

32 °F

(0.1 °C)

Clamp Pt 100 / Pt 1000

Clamp standard signal 0/4...20 mA

Analog signal 0/4...20 mA Clamp standard signal 0/4...20 mA

ProMinent offers DULCOMETER® measurement and control devices, DULCOTEST® sensor technology as well as ProMinent metering pumps for the creation of complete control circuits. Measuring, Control, metering and Recording all from one hand and optimally inter-adjusted.

Brochure

cad drawing

EC Declaration of Conformity

Flyer

Operating Instruction