Suggestions

Controller DULCOMETER diaLog X

The DULCOMETER diaLog X is a programmable controller used in a variety of water treatment applications to control metering pumps, valves, motors and other components to provide full automation of your chemical feed system.

Product description

The ultimate in water treatment control flexibility

DULCOMETER diaLog X continuously monitors and controls a wide range of measured parameters and digital inputs to optimize the water treatment process. The DULCOMETER diaLog X can control and monitor metering pumps, valves, motors, and other output components to provide full automation of your system using the different parameters or measured variables The physical variables to be determined by measuring. more in the glossary through the various inputs. Control of these various devices is accomplished through flexible programing of the open platform controller via multiple standards, connectivity options and communications protocols.

Features and Benefits

  • Excellent flexibility thanks to modular construction and easily extendible IO modules (input/output), allowing more sensors and pumps to be connected.
  • Up to two satellite units can be added for additional inputs and outputs, allowing more sensors and pumps to be connected.
  • Intuitive operation via the HMI (Human-Machine Interface) thanks to a clearly legible industrial display and robust keys for standard commands, such as calibration and monitoring.
  • Simple configuration of process settings as well as monitoring and visualisation of process data via a web server with freely configurable and preconfigured software modules.
  • Extensive overview and control of processes, e.g. cooling tower processes: All process data and alarms can be communicated to the process control system via fieldbuses such as Modbus RTU.
  • Advanced communication options: Various network protocols such as FTP or MQTT enable remote access and data management via Wi-Fi and LAN (Ethernet).

Field of application

The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.

  • Potable water and sewage treatment
  • Wastewater treatment
  • Industrial and process water treatment
  • Food and Beverage process water treatment

    Technical Details

    Comprehensive inputs and outputs

    • Up to 24 flexible sensor inputs and mA outputs (8 per device), e.g. CTFS sensor, linear polarisation resistor (LPR) corrosion sensor
    • Up to 30 output relays and pulse outputs (10 per device) to control pumps and other actuators
    • Up to 24 digital inputs (8 per device) to control level switches, water meters and remote switches
    • Up to 12 pulse frequency outputs
    • Up to 18 relays

    Communication options

    • In-built Modbus RTU and via gateways (BACnet, Modbus TCP, PROFINET)
    • Web interface via Wi-Fi and Ethernet, FTP server, rest API, MQTT client interface. The client interface is an intuitive remote control via a Wi-Fi or network connection to your PC or smartphone, e.g. for configuration settings or setpoint settings.
    • Configurable and managed via DULCONNEX.

    Technical Data

    Measured variables and measuring ranges

    Conductivity:
    With digital sensor CTFS at input A and B and via serial module D1: 0.1 - 10 mS/cm
    Via conductivity module L3 depending on sensor used (LMP, LFT): 50 μS cm - 20 mS/cm
    Via mA module AA with the inductive conductivity sensor ICT: 8 to 2 mS/cm, 20 mS/cm, 200 mS/cm
    Type of connection mV:
    pH: 0.00 ... 14.00
    ORP potential: -1,500 ... +1,500 mV
    Type of connection mA (amperometric measured variables, measuring ranges corresponding to sensors, 2 ppm, 10 ppm):
    Chlorine
    Chlorine dioxide
    Chlorite
    Bromine
    Ozone
    Hydrogen peroxide
    Peracetic acid
    Temperature:
    via Pt 100/Pt 1000, measuring range 32 … 302 °F (0 … 150 °C)

    Inputs and outputs

    Inputs
    4 plug-in module slots per unit for
    2-channel serial sensor input module
    2-channel conductivity input module
    2-channel mV input module
    2-channel mV/mA input module
    2-channel mA input module
    Outputs
    2-channel mA output module
    6 output relays as changeover contacts, of which 3 are potential-free and 3 are AC/DC
    4 pulse frequency outputs for controlling metering pumps
    8 digital control inputs for contact water meter, flow switch and pause for locking

    Resolution

    pH: 0.01 pH
    ORP: 1 mV
    Amperometric analysis (chlorine etc.): 0.001/0.01 ppm, 0.01 vol. %

    Accuracy

    0.3% based on the full-scale reading

    Temperature compensation

    Pt 100/Pt 1000 for pH

    Control characteristic

    P/PI/PID control

    Electrical Connection

    100 – 230 V, 50/60 Hz

    Ambient temperature

    23 … 122 °F (-5 … 50 °C) at max. 95% relative air humidity (non-condensing)

    Tests and approvals

    CE, MET, UK CA

    Housing material

    PC with flame proofing equipment

    Dimensions

    10.87 x 16.69 x 5.39 in (H x W x D)

    Enclosure rating

    Wall-mounted: IP 67

    Field bus connection

    Modbus RTU, additional field buses via gateway

    Downloads for Controller DULCOMETER diaLog X

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by Document type
    Load more matches ...
    No more matches available!

    Unfortunately, we did not find an appropriate match.

    All words written correctly?
    Search again with fewer or different search terms?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    The ultimate in water treatment control flexibility

    DULCOMETER diaLog X continuously monitors and controls a wide range of measured parameters and digital inputs to optimize the water treatment process. The DULCOMETER diaLog X can control and monitor metering pumps, valves, motors, and other output components to provide full automation of your system using the different parameters or measured variables The physical variables to be determined by measuring. more in the glossary through the various inputs. Control of these various devices is accomplished through flexible programing of the open platform controller via multiple standards, connectivity options and communications protocols.

    Features and Benefits

    • Excellent flexibility thanks to modular construction and easily extendible IO modules (input/output), allowing more sensors and pumps to be connected.
    • Up to two satellite units can be added for additional inputs and outputs, allowing more sensors and pumps to be connected.
    • Intuitive operation via the HMI (Human-Machine Interface) thanks to a clearly legible industrial display and robust keys for standard commands, such as calibration and monitoring.
    • Simple configuration of process settings as well as monitoring and visualisation of process data via a web server with freely configurable and preconfigured software modules.
    • Extensive overview and control of processes, e.g. cooling tower processes: All process data and alarms can be communicated to the process control system via fieldbuses such as Modbus RTU.
    • Advanced communication options: Various network protocols such as FTP or MQTT enable remote access and data management via Wi-Fi and LAN (Ethernet).

    Application

    Technical Data

    Downloads

    Find local ProMinent representative

    Contact us

    »We are looking forward to your enquiry.«

    +1 412-787-2484