Controller DULCOMETER diaLog DACb
The DULCOMETER DACb controller uses intelligent controller functions to close the control circuit between ProMinent DULCOTEST sensors and ProMinent metering pumps.
Product description
Intelligent measuring and controlling
The controller DULCOMETER diaLog DACb is our compact all-rounder for water analysis. With its specially designed functionalities, e.g. processing of interference variables and switchover of control parameters, it closes the control circuit between DULCOTEST sensors and ProMinent metering pumps. The measuring and control channels of the DULCOMETER diaLog DACb can be individually configured to meet customer requirements. Everything that you need for the reliable treatment of industrial and process water, drinking water as well as swimming pool water.
Features and Benefits
- One, two or three channels
- 2-way PID control
- Data and event logging with SD Card (optional)
- Three analog outputs
- Seven digital inputs
- Four frequency outputs
- Two powered relays
- Measured value trend display
- pH compensation for Free Chlorine
- Temperature compensation for pH, conductivity, and fluoride
- NEMA 4X enclosure
- LAN/ Ethernet connectivity
- PROFIBUS® DP, Profinet and Modbus RTU
- Optional 24V DC power
Field of application
The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.
- Potable water and sewage treatment
- Wastewater treatment
- Industrial and process water treatment
- Swimming pool water treatment
Technical Details
- Measured variables: pH, ORP, chlorine, chlorine dioxide, chlorite, bromine, conductivity, peracetic acid, hydrogen peroxide, ozone, dissolved oxygen and fluoride
- Installation, degree of protection: Combination housing (wall mounting, control panel mounting, pillar assembly) IP 67 and IP 66
- Control: three measuring and control channels, each with independent monodirectional PID controller (optional: two bidirectional PID controllers)
- 24 V DC protective low voltage supply e.g. by means of solar system or in the wet area of waterworks
- Temperature compensation for pH and for chlorine dioxide process sensor CDP, pH compensation for chlorine
- Digital inputs for the processing of control signals, e.g. of sample water limit contacts, remote stop control and to monitor the liquid levels in chemical storage tanks
- Control outputs for electronically controlled metering pumps and solenoid valves
- Interference variable processing: simple control of water parameters in flowing water by processing the flow in the control algorithm
- Adaptation of the controller setpoint to changed process conditions is possible via remote control by means of the mA signal of a PLC or with more stringent requirements via the field bus option
Technical Data
Measured variables and measuring ranges | Connection type mV: |
Resolution | pH: 0.01 |
Accuracy | 0.3% based on the full-scale reading |
Measurement input | pH/ORP (input resistance > 0.5 x 1012 Ω) |
Temperature compensation | Pt 100/Pt 1000 for pH, chlorine dioxide (CDP) sensor and fluoride |
Correction range temp. | 32…212 °F (0…100 °C) |
pH compensation range for chlorine | Sensor CLE 3 and CLE 3.1: 6.5 ... 8.5, sensor CBR: 6.5 ... 9.5 |
Disturbance signals | Flow via 0/4 … 20 mA signal or contact water meter, 1 - 500 Hz. The multiplicative interference variable can influence all channels, while the additive interference variable only influences one channel. |
Control characteristic | P/PID control |
Control | 2 or 3 bidirectional controls |
Analogue outputs | 2 (3) x 0/4 ... 20 mA electrically isolated, max. load 450 Ω, range and assignment (measured, correction, control variable) can be set |
Control outputs | 2 (4) pulse frequency outputs for controlling metering pumps |
Alarm relay | 250 V ~3 A, 700 VA contact type, changeover |
Digital control inputs | 4 (7) as a remote control input for the functions pause control / sample water fault, parameter set switch-over, level monitoring of chemical tanks |
Electrical Connection | 100 – 230 V, 50/60 Hz, 25 VA, optional 24 V DC |
Field bus connection | PROFIBUS® DP, Modbus RTU, PROFINET |
Ambient temperature | 32 … 122 °F (0 … 50 °C) (for use indoors or with a protective enclosure) |
Enclosure rating | Wall-mounted: IP 66 and IP 67 (NEMA 4X) |
Tests and approvals | CE and MET (corresponding to UL as per IEC 61010) |
Housing material | PC with flame proofing equipment |
Dimensions | 9.84 x 8.66 x 4.8 in (WxHxD) |
Weight | 2.9 | 1.3 lb | kg |
Standard equipment with basic measured variable
- PID controller with pulse frequency-based metering pump control for 2 metering pumps.
- 2 analogue outputs for measured value, correction value or control variable (depending on the optional equipment).
- 4 digital inputs for sample water fault detection, level switch, pause and parameter switch-over.
- 2 output relays can be programmed either as output for limit value, cycle timer, real-time timer or control output (depending on the optional equipment).
- Measured variables and language selection during commissioning.
- Temperature compensation of the pH, chlorine dioxide (CDP) and fluoride measurement via Pt100/Pt1000.
- 24 operating languages: all European languages as well as Chinese, Russian, Thai, Korean. The operating language is selected during commissioning and can be changed at any time by a keyboard shortcut. The documentation language is selected via the identity code. A data carrier is also supplied that contains all other languages.
- Device parametrisation is saved and transferred on an SD card.
- Calibration and event data logger (without SD card, data is saved in the controller).
- Interference variable processing (flow) via frequency (contact water meter).
- Subsequent upgrade of the software function by means of an activation key or firmware update.
Description of the possible measured variables as basic measured variables:
Module VA mV/temperature + mA sensor input:
- 1 sensor input for pH or ORP sensor and temperature sensor Pt100/Pt1000
- 1 sensor input for connecting, e.g. chlorine sensors, such as CBR or pH transducer pHV1 and fluoride including interference variable or pH compensation for chlorine.
Module AA mA/mA sensor input:
- 2 sensor inputs for connecting, e.g. chlorine sensors, such as CBR or pH transducer pHV1, including interference variable or pH compensation for chlorine.
Module VV mV/mV temperature sensor input:
- 2 sensor inputs for connecting pH and ORP sensors and temperature sensors Pt100/Pt1000, e.g. of type PHER, RHER, PHEI, RHEIC, Pt100SE
Module L3 conductivity temperature sensor input:
- 2 sensor inputs for connecting conductive conductivity sensors and temperature sensors Pt100/Pt1000, e.g. of type LFT, LMP
Optional equipment for third pH measuring channel
Package 2
- Third measuring and control variable pH via mV or mA with or pH compensation for chlorine without external setpoint specification via analogue signal for channel 1 without flow interference variable via mA for channel 1
- Third analogue output.
- Three additional digital inputs, e.g. for level monitoring, pause and sample water alarm.
- Control two additional metering pumps.
Package 3
- Third complete measuring and control channel, any measured variable, with PID controller.
- Third analogue output for measured value, correction value or control variable (depending on the optional equipment).
- Three additional digital inputs, e.g. for level monitoring, pause and sample water alarm.
- Temperature compensation of the pH, chlorine dioxide (CDP) and fluoride measurement.
Package 4
- Combination of packages 2 and 3 (only one channel for amperometric sensors is available with the mA interference variable).
Communication options
- Measurement data logger with SD card.
- Visualisation of the measured data using a web server via LAN and PC/tablet PC and web browser.
- PROFIBUS DP, Profinet or Modbus RTU.
Hardware upgrade
- Protective RC circuit for output relay: Protects the output relay if inductive loads are to be switched (e.g. solenoid valves or motors). Not with 24 V DC electrical connector.
Downloads for Controller DULCOMETER diaLog DACb
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
Intelligent measuring and controlling
The controller DULCOMETER diaLog DACb is our compact all-rounder for water analysis. With its specially designed functionalities, e.g. processing of interference variables and switchover of control parameters, it closes the control circuit between DULCOTEST sensors and ProMinent metering pumps. The measuring and control channels of the DULCOMETER diaLog DACb can be individually configured to meet customer requirements. Everything that you need for the reliable treatment of industrial and process water, drinking water as well as swimming pool water.
Features and Benefits
- One, two or three channels
- 2-way PID control
- Data and event logging with SD Card (optional)
- Three analog outputs
- Seven digital inputs
- Four frequency outputs
- Two powered relays
- Measured value trend display
- pH compensation for Free Chlorine
- Temperature compensation for pH, conductivity, and fluoride
- NEMA 4X enclosure
- LAN/ Ethernet connectivity
- PROFIBUS® DP, Profinet and Modbus RTU
- Optional 24V DC power
Video
Application
Field of application
The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.
- Potable water and sewage treatment
- Wastewater treatment
- Industrial and process water treatment
- Swimming pool water treatment
Technical Data
Technical Details
- Measured variables: pH, ORP, chlorine, chlorine dioxide, chlorite, bromine, conductivity, peracetic acid, hydrogen peroxide, ozone, dissolved oxygen and fluoride
- Installation, degree of protection: Combination housing (wall mounting, control panel mounting, pillar assembly) IP 67 and IP 66
- Control: three measuring and control channels, each with independent monodirectional PID controller (optional: two bidirectional PID controllers)
- 24 V DC protective low voltage supply e.g. by means of solar system or in the wet area of waterworks
- Temperature compensation for pH and for chlorine dioxide process sensor CDP, pH compensation for chlorine
- Digital inputs for the processing of control signals, e.g. of sample water limit contacts, remote stop control and to monitor the liquid levels in chemical storage tanks
- Control outputs for electronically controlled metering pumps and solenoid valves
- Interference variable processing: simple control of water parameters in flowing water by processing the flow in the control algorithm
- Adaptation of the controller setpoint to changed process conditions is possible via remote control by means of the mA signal of a PLC or with more stringent requirements via the field bus option
Technical Data
Measured variables and measuring ranges | Connection type mV: |
Resolution | pH: 0.01 |
Accuracy | 0.3% based on the full-scale reading |
Measurement input | pH/ORP (input resistance > 0.5 x 1012 Ω) |
Temperature compensation | Pt 100/Pt 1000 for pH, chlorine dioxide (CDP) sensor and fluoride |
Correction range temp. | 32…212 °F (0…100 °C) |
pH compensation range for chlorine | Sensor CLE 3 and CLE 3.1: 6.5 ... 8.5, sensor CBR: 6.5 ... 9.5 |
Disturbance signals | Flow via 0/4 … 20 mA signal or contact water meter, 1 - 500 Hz. The multiplicative interference variable can influence all channels, while the additive interference variable only influences one channel. |
Control characteristic | P/PID control |
Control | 2 or 3 bidirectional controls |
Analogue outputs | 2 (3) x 0/4 ... 20 mA electrically isolated, max. load 450 Ω, range and assignment (measured, correction, control variable) can be set |
Control outputs | 2 (4) pulse frequency outputs for controlling metering pumps |
Alarm relay | 250 V ~3 A, 700 VA contact type, changeover |
Digital control inputs | 4 (7) as a remote control input for the functions pause control / sample water fault, parameter set switch-over, level monitoring of chemical tanks |
Electrical Connection | 100 – 230 V, 50/60 Hz, 25 VA, optional 24 V DC |
Field bus connection | PROFIBUS® DP, Modbus RTU, PROFINET |
Ambient temperature | 32 … 122 °F (0 … 50 °C) (for use indoors or with a protective enclosure) |
Enclosure rating | Wall-mounted: IP 66 and IP 67 (NEMA 4X) |
Tests and approvals | CE and MET (corresponding to UL as per IEC 61010) |
Housing material | PC with flame proofing equipment |
Dimensions | 9.84 x 8.66 x 4.8 in (WxHxD) |
Weight | 2.9 | 1.3 lb | kg |
Standard equipment with basic measured variable
- PID controller with pulse frequency-based metering pump control for 2 metering pumps.
- 2 analogue outputs for measured value, correction value or control variable (depending on the optional equipment).
- 4 digital inputs for sample water fault detection, level switch, pause and parameter switch-over.
- 2 output relays can be programmed either as output for limit value, cycle timer, real-time timer or control output (depending on the optional equipment).
- Measured variables and language selection during commissioning.
- Temperature compensation of the pH, chlorine dioxide (CDP) and fluoride measurement via Pt100/Pt1000.
- 24 operating languages: all European languages as well as Chinese, Russian, Thai, Korean. The operating language is selected during commissioning and can be changed at any time by a keyboard shortcut. The documentation language is selected via the identity code. A data carrier is also supplied that contains all other languages.
- Device parametrisation is saved and transferred on an SD card.
- Calibration and event data logger (without SD card, data is saved in the controller).
- Interference variable processing (flow) via frequency (contact water meter).
- Subsequent upgrade of the software function by means of an activation key or firmware update.
Description of the possible measured variables as basic measured variables:
Module VA mV/temperature + mA sensor input:
- 1 sensor input for pH or ORP sensor and temperature sensor Pt100/Pt1000
- 1 sensor input for connecting, e.g. chlorine sensors, such as CBR or pH transducer pHV1 and fluoride including interference variable or pH compensation for chlorine.
Module AA mA/mA sensor input:
- 2 sensor inputs for connecting, e.g. chlorine sensors, such as CBR or pH transducer pHV1, including interference variable or pH compensation for chlorine.
Module VV mV/mV temperature sensor input:
- 2 sensor inputs for connecting pH and ORP sensors and temperature sensors Pt100/Pt1000, e.g. of type PHER, RHER, PHEI, RHEIC, Pt100SE
Module L3 conductivity temperature sensor input:
- 2 sensor inputs for connecting conductive conductivity sensors and temperature sensors Pt100/Pt1000, e.g. of type LFT, LMP
Optional equipment for third pH measuring channel
Package 2
- Third measuring and control variable pH via mV or mA with or pH compensation for chlorine without external setpoint specification via analogue signal for channel 1 without flow interference variable via mA for channel 1
- Third analogue output.
- Three additional digital inputs, e.g. for level monitoring, pause and sample water alarm.
- Control two additional metering pumps.
Package 3
- Third complete measuring and control channel, any measured variable, with PID controller.
- Third analogue output for measured value, correction value or control variable (depending on the optional equipment).
- Three additional digital inputs, e.g. for level monitoring, pause and sample water alarm.
- Temperature compensation of the pH, chlorine dioxide (CDP) and fluoride measurement.
Package 4
- Combination of packages 2 and 3 (only one channel for amperometric sensors is available with the mA interference variable).
Communication options
- Measurement data logger with SD card.
- Visualisation of the measured data using a web server via LAN and PC/tablet PC and web browser.
- PROFIBUS DP, Profinet or Modbus RTU.
Hardware upgrade
- Protective RC circuit for output relay: Protects the output relay if inductive loads are to be switched (e.g. solenoid valves or motors). Not with 24 V DC electrical connector.
Downloads