DULCOTEST ORP sensors

Typical measuring range -1,500...+1,500 mV; wider ranges are possible depending on the measuring device.

ORP measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real time. Can be used in water treatment or industrial process waters with strict requirements.

Product description

Reliable online measurement of ORP – with DULCOTEST sensors

Our product line of DULCOTEST ORP electrodes provides a wide range of sensors for different measuring tasks. The fields of application cover everything from simpler water treatment tasks through to industrial process waters with more stringent requirements in terms of temperature, pressure, contamination tolerance and chemical resistance.

The production of our electrodes is subject to very strict quality controls. Routine steps are automated but critical steps are carried out manually under expert supervision. In this way we achieve optimum reproducible quality and cost reduction.

ORP potential is a measured variable that quantifies the presence of oxidants or reducing agents in a medium under specific conditions on a non-selective basis. Measuring this parameter is relatively inexpensive, but does have some drawbacks: no selective measurement of a specific oxidant / reducing agent, high dependence on pH, measuring signal tends towards a saturation curve as concentration increases. To measure specific reducing agents and oxidants selectively, without the above disadvantages, suitable amperometric sensors are used (e.g. chlorine sensors).

Your benefits

  • Precise and reliable measurement enables efficient processes and excellent process reliability
  • The wide choice of sensor types with different constructions makes them reliable components in many applications
  • A long service life is achieved through the use of select quality materials for the measuring electrodes and diaphragms and a stable reference system. This minimises both downtime and maintenance
  • With short storage times and fast delivery, your sensors can be up and running very quickly and you can make maximum use of their service life (all glass sensors start to age as soon as they leave production)
  • Wide range of special versions for fitting length, cable length and plugs for made-to-measure connection to your process
  • Unique label for OEM partners

Field of application

The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.

  • Cyanide detoxification at a high pH value by means of oxidation
  • Chromate detoxification at a low pH value by means of reduction
  • Monitoring of disinfection effectiveness with oxidant metering
  • Swimming pool water, potable water
  • Process water
  • Chemically contaminated water
  • Cooling water, waste water

    Technical Details

    • Selection of sensor type according to the application
    • The insertion angle must be > 15° from the horizontal
    • Max flow < 0.8 m/s
    • With cable lengths >10 m, use the 4-20 mA transducer type PHV1
    • Calibration using quality buffer solutions

    ORP Sensor RHES-Pt-SE

    ORP sensor optimised for use in potable water treatment, swimming pools/hot tubs at up to 140 °F/43 psi (60 °C/3 bar)

    Your Benefits

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • Diaphragm and reference system optimised for use in swimming pools and for potable water
    • Ceramic diaphragm with special material, optimised size and optimised pore diameter
    • Long service life due to reduced diffusion ("bleeding") of the electrolyte
    • Long service life due to the material, which is inert to aggressive disinfectants
    • Stable reference system
    • Rotating sensor head sleeve. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding moisture on the plug-in contacts
    • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

    Temperature

    32…140 °F (0…60 °C)

    Max. pressure

    44 psi

    Min. conductivity

    150 µS/cm

    Electrolyte

    Gel containing potassium chloride

    ORP electrode

    Platinum

    Diaphragm

    Ceramic

    Sensor shaft

    Glass

    Shaft diameter

    0.47 inch

    Installation length

    4.72 ±0.12 inch

    Fitting position

    Vertical up to +25°

    Thread

    PG 13.5

    Electrical Connection

    SN6 plug-in head, rotatable with a ProMinent cable

    Enclosure rating

    IP 65

    Process integration

    Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube

    Controllers

    all DULCOMETER controllers

    Typical applications

    Swimming pools, whirlpools, potable water

    Resistance to

    Disinfectant

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm

    Installation length

    Order no.

    RHES-Pt-SE SLg100

    3.94 ±0.12 inch

    1051746

    RHES-Pt-SE

    4.72 ±0.12 inch

    150703

    ORP Sensor RHES-Au-SE

    ORP sensor optimised for use in potable water treatment, swimming pools/hot tubs when electrolysis processes are used for disinfection and with ozone treatment at up to 140 °F/43 psi (60 °C/3 bar)

    Your Benefits

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • Gold electrode to prevent faults caused by products from those electrolysis processes where the electrodes are immersed directly into the sample water
    • Diaphragm and reference system optimised for use in swimming pools and for potable water
    • Ceramic diaphragm with special material, optimised size and optimised pore diameter
    • Long service life due to reduced diffusion ("bleeding") of the electrolyte
    • Long service life thanks to material, which is inert to aggressive disinfectants
    • Stable reference system
    • Rotating sensor head sleeve. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding moisture on the plug-in contacts
    • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

    Temperature

    32…140 °F (0…60 °C)

    Max. pressure

    44 psi

    Min. conductivity

    150 µS/cm

    Electrolyte

    Gel containing potassium chloride

    ORP electrode

    Gold

    Diaphragm

    Ceramic

    Sensor shaft

    Glass

    Shaft diameter

    0.47 inch

    Installation length

    4.72 ±0.12 inch

    Fitting position

    Vertical up to +25°

    Thread

    PG 13.5

    Electrical Connection

    SN6 plug-in head, rotatable with a ProMinent cable

    Enclosure rating

    IP 65

    Process integration

    Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube

    Controllers

    all DULCOMETER controllers

    Typical applications

    Swimming pools, whirlpools, potable water, with disinfectants from electrolysis processes (electrodes directly in the process water).

    Resistance to

    Disinfectant, by-products from electrolysis process and from ozone treatment process

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm

    Installation length

    Order no.

    RHES-Au-SE

    4.72 ±0.12 inch

    1044544

    RHES-AU-SE Slg 100

    3.94 ±0.12 inch

    1092570

    ORP Sensor RHEP-Pt-SE

    ORP sensor optimised for use with clear process water and conditions of up to 176 °F/87 psi (80 °C/6 bar)

    Your Benefits

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • Diaphragm and reference system optimised for exacting process requirements
    • Ceramic diaphragm with special material, optimised size and optimised pore diameter
    • Long service life due to reduced diffusion ("bleeding") of the electrolyte
    • Long service life thanks to material, which is inert to aggressive chemicals
    • Stable reference system for high pressure / temperature requirements
    • Rotating sensor head sleeve. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding moisture on the plug-in contacts
    • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

    Temperature

    32…176 °F (0…80 °C)

    Max. pressure

    87 psi

    Min. conductivity

    150 µS/cm

    Electrolyte

    Gel containing potassium chloride

    ORP electrode

    Platinum

    Diaphragm

    Ceramic

    Sensor shaft

    Glass

    Shaft diameter

    0.59 inch

    Installation length

    4.72 ±0.12 inch

    Fitting position

    Vertical up to +25°

    Thread

    PG 13.5

    Electrical Connection

    SN6 plug-in head, rotatable with a ProMinent cable

    Enclosure rating

    IP 65

    Process integration

    Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube

    Controllers

    all DULCOMETER controllers

    Typical applications

    Swimming pools during pressurisation for higher temperatures and pressures, potable and industrial water, electroplating.

    Resistance to

    Disinfectant, not suitable for media containing ozone, cyanides, electrolysis processes (electrodes directly in the sample water)

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm

    Installation length

    Order no.

    RHEP-Pt-SE

    4.72 ±0.12 inch

    150094

    RHEP-PT -SE SLG100

    3.94 ±0.12 inch

    150952

    ORP Sensor RHEP-Au-SE

    ORP sensor optimised for use with clear process water when electrolysis processes are used for disinfection and with ozone treatment and with cyanide detoxification at conditions of up to 176 °F/87 psi (80 °C/6 bar)

    Your Benefits

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • Gold electrode to prevent faults caused by products from those electrolysis processes where the electrodes are immersed directly into the sample water
    • Diaphragm and reference system optimised for exacting process requirements
    • Ceramic diaphragm with special material, optimised size and optimised pore diameter
    • Long service life due to reduced diffusion ("bleeding") of the electrolyte
    • Long service life due to the material, which is inert to aggressive chemicals
    • Stable reference system for high pressure / temperature requirements
    • Rotating sensor head sleeve. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding moisture on the plug-in contacts
    • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

    Temperature

    32…176 °F (0…80 °C)

    Max. pressure

    87 psi

    Min. conductivity

    150 µS/cm

    Electrolyte

    Gel containing potassium chloride

    ORP electrode

    Gold

    Diaphragm

    Ceramic

    Sensor shaft

    Glass

    Shaft diameter

    0.59 inch

    Installation length

    4.72 ±0.12 inch

    Fitting position

    Vertical up to +25°

    Thread

    PG 13.5

    Electrical Connection

    SN6 plug-in head, rotatable with a ProMinent cable

    Enclosure rating

    IP 65

    Process integration

    Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube

    Controllers

    all DULCOMETER controllers

    Typical applications

    Cyanide detoxification, ozone monitoring

    Resistance to

    Disinfectant, by-products from electrolysis process and from ozone treatment process, cyanides

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm

    Installation length

    Order no.

    RHEP-Au-SE

    4.72 ±0.12 inch

    1003875

    ORP Sensor RHER-Pt-SE

    ORP sensor optimised for use in contaminated water containing solids and for low conductivity of > 50 μS/cm at up to 176 °F/87 psi (80 °C/6 bar)

    Your Benefits

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • The large dirt-repellent Teflon® diaphragm prevents the reference system from becoming blocked up
    • Long service life when solids are present
    • High-viscosity electrolyte combined with a salt reservoir prevents the electrolyte from "bleeding"
    • Long service life without drifts when there is clear water with low conductivity
    • Rotating sensor head sleeve. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding moisture on the plug-in contacts
    • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

    Temperature

    32…176 °F (0…80 °C)

    Max. pressure

    87 psi

    Min. conductivity

    50 µS/cm

    Electrolyte

    Electrolyte with KCI supplement (salt rings in the reference electrolyte)

    ORP electrode

    Platinum

    Diaphragm

    PTFE ring diaphragm

    Sensor shaft

    Glass

    Shaft diameter

    0.47 inch

    Installation length

    4.72 ±0.12 inch

    Fitting position

    Vertical up to +25°

    Thread

    PG 13.5

    Electrical Connection

    SN6 plug-in head/other versions on request

    Enclosure rating

    IP 65

    Process integration

    Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube

    Controllers

    all DULCOMETER controllers

    Typical applications

    Municipal and industrial waste water, cooling water, process water, chemical applications, paper manufacturing. In general for water with a noticeable solid fraction

    Resistance to

    Disinfectant, solids content (turbid types of water)

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, Teflon ring diaphragm, polymer electrolyte

    Installation length

    Order no.

    RHER-Pt-SE

    4.72 ±0.12 inch

    1002534

    ORP sensor RHER-DJ-Pt-SE

    ORP sensor optimised for use in contaminated water containing solids and for low conductivity of > 10 μS/cm at up to 176 °F/87 psi (80 °C/6 bar)

    The benefits for you

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • The large dirt-repellent Teflon® diaphragm prevents the reference system from becoming blocked up
    • Long service life when solids are present
    • High-viscosity electrolyte combined with a salt reservoir prevents the electrolyte from "bleeding"
    • Long service life without drifts when there is clear water with low conductivity
    • Rotating sensor head sleeve. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding moisture on the plug-in contacts
    • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

    Temperature

    32…176 °F (0…80 °C)

    Max. pressure

    87 psi

    Min. conductivity

    10 µS/cm

    Electrolyte

    Electrolyte with KCI supplement (salt rings in the reference electrolyte)

    ORP electrode

    Platinum

    Diaphragm

    2 x PTFE ring diaphragm, double junction

    Sensor shaft

    Glass

    Shaft diameter

    0.47 inch

    Installation length

    4.72 ±0.12 inch

    Fitting position

    Vertical up to +25°

    Thread

    PG 13.5

    Electrical Connection

    SN6 plug-in head/other versions on request

    Enclosure rating

    IP 65

    Process integration

    Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube

    Controllers

    all DULCOMETER controllers

    Typical applications

    Municipal and industrial waste water, cooling water, process water, chemical applications, paper manufacturing. In general for water with a noticeable solid fraction

    Resistance to

    Disinfectant, solids content (turbid types of water)

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, Teflon ring diaphragm, polymer electrolyte

    Installation length

    Order no.

    RHER-DJ-Pt-SE

    4.72 ±0.12 inch

    1112882

    ORP Sensor RHEX-Pt-SE

    ORP sensor optimised for use with contaminated water with a high solids content at 87 psi/212 °F (6 bar/100 °C) or 232 psi/77 °F (16 bar/25 °C)

    Your Benefits

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • Diaphragm and reference system optimised for extremely high solids content
    • The solid electrolyte makes the diaphragm redundant and prevents the reference system from becoming blocked up
    • Long service life when sludge is present due to lack of a diaphragm
    • Long service life as the solid electrolyte prevents the electrolyte from "bleeding"
    • Stable reference system
    • Rotating sensor head sleeve. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding moisture on the plug-in contacts
    • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

    Temperature

    32…212 °F (0…100 °C)

    Max. pressure

    232 psi (77 °F / 25 °C) 87 psi (212 °F / 100 °C)

    Min. conductivity

    500 µS/cm

    Electrolyte

    Polymer containing potassium chloride (solid)

    ORP electrode

    Platinum

    Diaphragm

    Circular gap (solid electrolyte)

    Sensor shaft

    Glass

    Shaft diameter

    0.47 inch

    Installation length

    4.72 ±0.12 inch

    Fitting position

    Vertical up to +25°

    Thread

    PG 13.5

    Electrical Connection

    SN6 plug-in head/other versions on request

    Enclosure rating

    IP 65

    Process integration

    Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube

    Controllers

    all DULCOMETER controllers

    Typical applications

    Waste water, industrial water, process chemistry, emulsions, suspensions, protein-containing media. In general for water with a high solid fraction. Not suitable for clear media. Not suitable for media with oxidation agents.

    Resistance to

    Solids content (turbid types of water), sludge, emulsions

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, no diaphragm, polymer electrolyte

    Installation length

    Order no.

    RHEX-Pt-SE

    4.72 ±0.12 inch

    305097

    ORP Sensor RHEIC-Pt-SE

    ORP sensor optimised for use in industrial waste water/water – with DULCOTEST sensors.

    Your Benefits

    • Mechanically resistant platinum dome permits lengthy use even when exposed to abrasive particles
    • Large dirt-repellent Teflon diaphragm protects against unwanted blockage of the reference
    • Double junction reference system for stability with chemically polluted water
    • Large electrolyte reservoir for long service lives
    • Solid high-grade plastic housing with integrated process connection for direct installation in the process with ½" and ¾" NPT thread

    Temperature

    32…176 °F (0…80 °C)

    Max. pressure

    87 psi

    Min. conductivity

    50 µS/cm

    Electrolyte

    Gel containing potassium chloride with a large KCI reservoir of gel

    Diaphragm

    PTFE ring diaphragm

    Sensor shaft

    Plastic

    Shaft diameter

    0.67 ±0.008 inch (below the ½” NPT thread), 0.87 ±0.008 inch (below the ¾” thread)

    Installation length

    0.79 ±0.008 inch (from the lower end of the ½” thread), 2.36 ±0.008 inch (from the lower end of the ¾” thread)

    Fitting position

    Vertical up to +25°

    Thread

    ½” and ¾” NPT thread

    Electrical Connection

    SN6 plug-in head, rotatable with a ProMinent cable

    Enclosure rating

    IP 65

    Process integration

    Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube

    Controllers

    all DULCOMETER controllers

    Typical applications

    Municipal and industrial waste water Cooling water, process water, water in the chemical industry and paper making, generally for water with a solid matter fraction.

    Resistance to

    Disinfectant, solids content (turbid water), water-soluble chemicals

    Measuring principle, technology

    direct potentiometric measurement, 2 probes, double junction, gel electrolyte, large Teflon diaphragm, separate temperature measurement for temperature compensation needed

    Order no.

    RHEIC-Pt-SE

    1082281

    ORP Sensor RHEN-Pt-SE

    Refillable ORP sensor optimised for use with chemically contaminated water at up to 176 °F (80 °C)/without excess pressure

    Your Benefits

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • Renewable liquid electrolyte by continuous replenishment from an electrolyte bottle installed above the electrode
    • 1 ceramic diaphragm made of special material, with an optimised size and with optimised pore diameter
    • Long service life in the presence of chemicals dissolved in the water, which could contaminate the reference system
    • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

    Temperature

    32…176 °F (0…80 °C)

    Max. pressure

    Operation at atmospheric pressure

    Min. conductivity

    150 µS/cm

    Electrolyte

    KCL electrolyte, refillable

    ORP electrode

    Platinum

    Diaphragm

    Ceramic

    Sensor shaft

    Glass

    Shaft diameter

    0.47 inch

    Installation length

    4.72 ±0.12 inch

    Fitting position

    Vertical up to +25°

    Thread

    PG 13.5

    Electrical Connection

    SN6 plug-in head/other versions on request

    Enclosure rating

    IP 65

    Process integration

    By tripod or manually

    Controllers

    all DULCOMETER controllers

    Typical applications

    Waste water, cooling water, chemically contaminated water, only clear types of water.

    Resistance to

    Disinfectant, chemicals dissolved in water

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, liquid electrolyte, 1 ceramic diaphragm

    Installation length

    Order no.

    RHEN-Pt-SE

    4.72 ±0.12 inch

    305091

    Delivered without PE storage tank and hose

    ORP Sensor RHEK-Pt-S

    ORP sensor with plastic shaft for use with manual measuring instruments, optimised for use in potable water treatment, swimming pools/hot tubs at up to 140 °F/43 psi (60 °C/3 bar)

    Your Benefits

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • Diaphragm and reference system optimised for use in swimming pools and for potable water
    • With plastic shaft to prevent glass breakage
    • Mechanical protection of the glass diaphragm
    • Ceramic diaphragm with special material, optimised size and optimised pore diameter
    • Long service life due to reduced diffusion ("bleeding") of the electrolyte
    • Long service life due to the material, which is inert to aggressive disinfectants
    • Stable reference system
    • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

    Temperature

    32…140 °F (0…60 °C)

    Max. pressure

    Operation at atmospheric pressure

    Min. conductivity

    150 µS/cm

    Electrolyte

    Gel containing potassium chloride

    ORP electrode

    Platinum

    Diaphragm

    Ceramic

    Sensor shaft

    Polycarbonate

    Shaft diameter

    0.47 inch

    Installation length

    4.92 ±0.12 inch

    Fitting position

    Vertical up to +25°

    Thread

    none

    Electrical Connection

    SN6 plug-in head, rotatable with a ProMinent cable

    Enclosure rating

    IP 65

    Process integration

    By tripod or manually

    Controllers

    all DULCOMETER controllers

    Typical applications

    Manual measurement e.g. swimming pools, potable water, aquarium water

    Resistance to

    Disinfectant

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm

    Installation length

    Order no.

    RHEK-Pt-S

    4.92 ±0.12 inch

    305052

    ORP Sensor RHEK-Pt-SE

    ORP sensor with plastic shaft, optimised for use in potable water treatment, swimming pools/hot tubs at up to 140 °F/43 psi (60 °C/3 bar)

    Your Benefits

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • Diaphragm and reference system optimised for use in swimming pools and for potable water
    • With plastic shaft to prevent glass breakage
    • Mechanical protection of the glass diaphragm
    • Ceramic diaphragm with special material, optimised size and optimised pore diameter
    • Long service life due to reduced diffusion ("bleeding") of the electrolyte
    • Long service life due to the material, which is inert to aggressive disinfectants
    • Stable reference system
    • Rotating sensor head sleeve. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding moisture on the plug-in contacts
    • Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)

    Temperature

    32…140 °F (0…60 °C)

    Max. pressure

    44 psi

    Min. conductivity

    150 µS/cm

    Electrolyte

    Gel containing potassium chloride

    ORP electrode

    Platinum

    Diaphragm

    Ceramic

    Sensor shaft

    Polycarbonate

    Shaft diameter

    0.47 inch

    Installation length

    4.72 ±0.12 inch

    Fitting position

    Vertical up to +25°

    Thread

    PG 13.5

    Electrical Connection

    SN6 plug-in head, rotatable with a ProMinent cable

    Enclosure rating

    IP 65

    Process integration

    Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube

    Controllers

    all DULCOMETER controllers

    Typical applications

    Swimming pool, potable water, aquariums

    Resistance to

    Disinfectant

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm

    Installation length

    Order no.

    RHEK-Pt-SE

    4.72 ±0.12 inch

    1028459

    ORP Sensor RHEK-L Pt-SE

    ORP sensor with plastic shaft, optimised for vertical to horizontal installation position for use in potable water treatment, swimming pools/hot tubs at up to 140 °F/43 psi (60 °C/3 bar)

    Your Benefits

    • Electrochemical combination electrode: ORP and reference electrode integrated
    • With plastic shaft to prevent glass breakage
    • Horizontal (level) installation possible (90° angle) (usually limited to 0 - 75° angle)
    • Diaphragm and reference system optimised for use in swimming pools and for potable water
    • Ceramic diaphragm with special material, optimised size and optimised pore diameter
    • Long service life due to reduced diffusion ("bleeding") of the electrolyte
    • Rotating sensor head sleeve. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding moisture on the plug-in contacts
    • Long service life due to the material, which is inert to aggressive disinfectants
    • Stable reference system

    Temperature

    32…140 °F (0…60 °C)

    Max. pressure

    44 psi

    Min. conductivity

    150 µS/cm

    Electrolyte

    Gel containing potassium chloride

    ORP electrode

    Platinum

    Diaphragm

    Ceramic

    Sensor shaft

    Polycarbonate

    Shaft diameter

    0.47 inch

    Installation length

    4.72 ±0.12 inch

    Fitting position

    Vertical to horizontal

    Thread

    PG 13.5

    Electrical Connection

    SN6 plug-in head, rotatable with a ProMinent cable

    Enclosure rating

    IP 65

    Process integration

    Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube

    Controllers

    all DULCOMETER controllers

    Typical applications

    Swimming pools, potable water, aquariums, horizontal installation possible

    Resistance to

    Disinfectant

    Measuring principle, technology

    Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm

    Installation length

    Order no.

    RHEK-L Pt-SE

    4.72 ±0.12 inch

    1034919

    Downloads for DULCOTEST ORP sensors

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by A to Z
    Load more matches ...
    No more matches available!

    Unfortunately, we did not find an appropriate match.

    All words written correctly?
    Search again with fewer or different search terms?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    Reliable online measurement of ORP – with DULCOTEST sensors

    Our product line of DULCOTEST ORP electrodes provides a wide range of sensors for different measuring tasks. The fields of application cover everything from simpler water treatment tasks through to industrial process waters with more stringent requirements in terms of temperature, pressure, contamination tolerance and chemical resistance.

    The production of our electrodes is subject to very strict quality controls. Routine steps are automated but critical steps are carried out manually under expert supervision. In this way we achieve optimum reproducible quality and cost reduction.

    ORP potential is a measured variable that quantifies the presence of oxidants or reducing agents in a medium under specific conditions on a non-selective basis. Measuring this parameter is relatively inexpensive, but does have some drawbacks: no selective measurement of a specific oxidant / reducing agent, high dependence on pH, measuring signal tends towards a saturation curve as concentration increases. To measure specific reducing agents and oxidants selectively, without the above disadvantages, suitable amperometric sensors are used (e.g. chlorine sensors).

    Your benefits

    • Precise and reliable measurement enables efficient processes and excellent process reliability
    • The wide choice of sensor types with different constructions makes them reliable components in many applications
    • A long service life is achieved through the use of select quality materials for the measuring electrodes and diaphragms and a stable reference system. This minimises both downtime and maintenance
    • With short storage times and fast delivery, your sensors can be up and running very quickly and you can make maximum use of their service life (all glass sensors start to age as soon as they leave production)
    • Wide range of special versions for fitting length, cable length and plugs for made-to-measure connection to your process
    • Unique label for OEM partners

    Video

    Application

    Technical Data

    Downloads

    Find local ProMinent representative

    Contact us

    »We are looking forward to your enquiry.«

    +1 412-787-2484 

    Matching Products

    Chlorine dioxide measurement with DULCOTEST sensors offers precise, reliable, application-specific measured values in real time for all oxidation and disinfection tasks.

    more

    pH measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real time. Control, regulate and monitor chemical processes with the aid of precise measured values.

    more

    The application-based DULCOTEST sensors for free chlorine deliver precise measured values and a high degree of monitoring and process reliability in any disinfection application.

    more

    Disinfection of swimming pool water with the application-optimised DULCOTEST sensors for total available chlorine - exact measured values and high process reliability guaranteed.

    more

    Bromine measurement with DULCOTEST sensors: Safe metering in disinfection processes with bromine. The robustness of the sensors makes them suitable for a very wide range of water qualities.

    more

    Measuring ozone in oxidation and disinfection applications: DULCOTEST sensors offer precise, reliable, application-specific measured values in real time.

    more

    The DULCOMETER DACb controller uses intelligent controller functions to close the control circuit between ProMinent DULCOTEST sensors and ProMinent metering pumps.

    more

    The DULCOMETER Type D1Cb is suitable for applications in drinking water, wastewater, and cooling water treatment. The single channel measuring and control unit D1Cb is equipped for all-important measured variables for basic applications in water treatment and with an error and calibration logbook.

    more

    Chlorine dioxide system, which continuously produces ClO2 according to the acid/chlorite method with diluted chemicals. Extremely simple operation, clear construction, analogue control, manual control or via contacts.

    more

    The measuring and control device DULCOMETER Compact for pH and redox measured variables is equipped with the standard functions for use in water treatment plants, allowing the operator to switch between the measured variables pH and redox, and between P and PID control characteristics.

    more

    OZONFILT OZMa is synonymous with maximum operational safety and minimal operating costs. The ozone generator is maintenance-free and generates up to 0.93 lb/h (420 g/h) of ozone from compressed air.

    more

    Electrolysis systems of type CHLORINSITU V take the place of the chlorine gas system in the swimming pool and only need salt, water and electricity to do so.

    more