DULCOTEST sensors for ozone

Measuring range 0.02 – 2 mg/l

Measuring ozone in oxidation and disinfection applications: DULCOTEST sensors offer precise, reliable, application-specific measured values in real time.

Product description

Reliable online measurement of ozone – with DULCOTEST sensors.

To monitor or control clear water, for instance in the disinfection of potable water, there is the tried-and-tested standard ozone sensor type OZE3 mA. The innovative sensor type OZR1 can be used in polluted waters, e.g. raw water for potable water generation, cooling water and waste water. When monitoring for the absence of ozone, the active carbon filters indicate that ozone is getting through.

Features and Benefits

  • Two application-optimised sensor types available
  • Precise, real-time amperometric measurement for efficient process control (short response time)
  • Amperometric measuring eliminates interference caused by turbidity or colouration
  • Integrated temperature compensation eliminates interference caused by influence of temperature
  • Diaphragm-covered electrodes for reduced dependence on flow, cross-sensitivities, substances in water and film-forming media
  • Diaphragm-covered measuring electrodes embedded in an electrolyte ensure long service life. This maintains optimum measuring conditions regardless of process conditions

Field of application

The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.

  • Type OZE3: Swimming pool water, potable water
  • Type OZR1: Raw water, cooling water, industrial water, process water, waste water, ozone penetration monitoring

    Technical Details

    • pH range: 4.0 … 11.0 Stability range of ozone
    • Temperature 41 … 104 °F (5 … 40 °C)
    • Pressure max. 15 psi
    • Flow 8 … 16 gph (30 … 60 l/h) (in DGM or DLG III)
    • Supply voltage 16 … 24 V DC (two-wire)
    • Output signal 4 … 20 mA

    Ozone sensor OZE 3-mA

    Standard sensor for measuring ozone in clear water. For operation on controllers with 4-20 mA input

    Your Benefits

    • Measured variable: Ozone, without cross sensitivity to chlorine, hydrogen peroxide
    • Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or ingredients in the water

    Measured variable

    Ozone (O3)

    Reference method

    DPD4

    pH-range

    4.0…11.0

    Cross sensitivity

    Chlorine dioxide

    Temperature

    41…104 °F (5…40 °C)

    Max. pressure

    15 psi

    Flow

    DGMa, DLG III: 5.28 ... 15.85 gph (20 ... 60 l/h)
    BAMa: 1.32 ... 26.42 gph (5 ... 100 l/h) (depending on design)

    Supply voltage

    16...24 V DC (2-wire)

    Output signal

    4-20 mA ≈ measuring range, temperature-compensated, uncalibrated, not electrically isolated

    Selectivity

    Ozone as against free chlorine, combined chlorine, hydrogen peroxide

    Process integration

    Bypass: open sample water outlet

    Controllers

    D1C

    Typical applications

    Potable water and swimming pool water.

    Resistance to

    Salts, acids, alkalis. Not surfactants

    Measuring principle, technology

    Amperometric, 2 electrodes, diaphragm-covered

    Measuring range

    Order no.

    OZE 3-mA

    0.02…2.0 mg/l

    792957

    Note: A mounting kit (order no. 815079) is required for initial fitting of the ozone sensors in the in-line probe housing DLG III.

    Ozone sensor OZR 1-mA

    Sensor for measuring and monitoring the absence of ozone, also suitable for use in contaminated water. For operation on controllers with 4-20 mA input

    Your Benefits

    • Measured variable: Ozone, without cross sensitivity to chlorine, hydrogen peroxide
    • Diaphragm-covered sensor (encapsulated) minimises faults caused by changing flow or ingredients in the water
    • Suitable also for monitoring the absence of ozone (rupture monitoring on filters) and for discontinuous ozone treatment processes
    • Resistance to films of dirt by pore-free diaphragm

    Measured variable

    Ozone (O3)

    Reference method

    DPD4

    pH-range

    4.0…11.0

    Cross sensitivity

    chlorine dioxide, peracetic acid, bromine, bromamine

    Temperature

    41…104 °F (5…40 °C)

    Max. pressure

    15 psi

    Flow

    DGMa, DLG III: 7.93 ... 15.85 gph (30 ... 60 l/h)
    BAMa: 1.32 ... 26.42 gph (5 ... 100 l/h) (depending on design)

    Supply voltage

    16...24 V DC (2-wire)

    Output signal

    4-20 mA ≈ measuring range, temperature-compensated, uncalibrated, not electrically isolated

    Response time t90 after 1 month with 0.00 ppm ozone

    <210 s

    Selectivity

    Non-selective

    Process integration

    Bypass: open sample water outlet

    Controllers

    D1C, DAC

    Typical applications

    Potable water, swimming pool water, process, service or cooling water, monitoring the ozone breakdown of filters.

    Resistance to

    Salts, acids, alkalis, surfactants, dirt films

    Measuring principle, technology

    Amperometric, 2 electrodes, diaphragm-covered

    Measuring range

    Order no.

    OZR 1-mA-0.5 ppm

    0.01…0.5 mg/l

    1118883

    OZR 1-mA-2 ppm

    0.02…2.0 mg/l

    1051647

    OZR 1-mA-10 ppm

    0.1…10.0 mg/l

    1118925

    Note: A mounting kit (order no. 815079) is required for initial fitting of the ozone sensors in the in-line probe housing DLG III.

    Downloads for DULCOTEST sensors for ozone

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by Document type
    Load more matches ...
    No more matches available!

    Unfortunately, we did not find an appropriate match.

    All words written correctly?
    Search again with fewer or different search terms?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    Reliable online measurement of ozone – with DULCOTEST sensors.

    To monitor or control clear water, for instance in the disinfection of potable water, there is the tried-and-tested standard ozone sensor type OZE3 mA. The innovative sensor type OZR1 can be used in polluted waters, e.g. raw water for potable water generation, cooling water and waste water. When monitoring for the absence of ozone, the active carbon filters indicate that ozone is getting through.

    Features and Benefits

    • Two application-optimised sensor types available
    • Precise, real-time amperometric measurement for efficient process control (short response time)
    • Amperometric measuring eliminates interference caused by turbidity or colouration
    • Integrated temperature compensation eliminates interference caused by influence of temperature
    • Diaphragm-covered electrodes for reduced dependence on flow, cross-sensitivities, substances in water and film-forming media
    • Diaphragm-covered measuring electrodes embedded in an electrolyte ensure long service life. This maintains optimum measuring conditions regardless of process conditions

    Application

    Technical Data

    Downloads

    Find local ProMinent representative

    Contact us

    »We are looking forward to your enquiry.«

    +1 412-787-2484 

    Matching Products

    ORP measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real time. Can be used in water treatment or industrial process waters with strict requirements.

    more

    The DULCOMETER DACb controller uses intelligent controller functions to close the control circuit between ProMinent DULCOTEST sensors and ProMinent metering pumps.

    more

    The DULCOMETER Type D1Cb is suitable for applications in drinking water, wastewater, and cooling water treatment. The single channel measuring and control unit D1Cb is equipped for all-important measured variables for basic applications in water treatment and with an error and calibration logbook.

    more

    Photometers measure nearly all disinfectants and the pH value based on the photometric principle. They are portable, compact and make safe, simple measurement possible.

    more

    OZONFILT OZMa is synonymous with maximum operational safety and minimal operating costs. The ozone generator is maintenance-free and generates up to 0.93 lb/h (420 g/h) of ozone from compressed air.

    more

    OZONFILT OZVb is powerful and compact and is ideal for efficient ozone generation from compressed air in the output range of up to 0.15 lb/h. The turnkey ozone system including mixing equipment offers everything you need for safe and seamless operation.

    more

    OZONFILT Compact OMVb is a complete, ready-to-use system solution for the generation and metering of ozone.

    more