DULCOMETER DMT 2-Wire-Transmitters
Compact 2-wire-transmitter with microprocessor technology. Reliable monitoring for pH, Redox, Chlorine, conductive conductivity, and temperature applications.
Product description
The compact 2-wire transmitter – the link to the PLC and DULCOMETER.
DULCOMETER DMT type transmitters are compact 2-wire transmitters for measured variables The physical variables to be determined by measuring. more in the glossary pH, redox, chlorine, conductive conductivity Conductive conductivity sensors measure the electrolytic conductivity indirectly via ... more in the glossary, temperature.
Easily combined with programmable memory controllers.
Features and Benefits
- Reliable measurement
- High level of operating safety, e.g., probe monitoring (pH), electrical isolation
- Simple flexible installation
- Full text user guidance
- Automatic buffer recognition (pH)
- Auto ranging (conductivity)
- Compact design
- Switch between pH, redox and temperature
Field of application
The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.
- Process control
- Food and beverage industry
- Chemical and pharmaceutical industries
- Water treatment
- Wastewater treatment
- Power plant
Technical Details
Measured Variables:
- pH
- ORP (Redox)
- Chlorine (Free or Total)
- Conductivity (conductive)
- Temperature
Technical Data
Measuring range | pH - 1.00 … 15.00 |
Cell constant | 0.006 … 12.0/cm for conductivity |
Resolution | 0.01 pH |
Accuracy | 0.5% from measurement range |
Measurement input | mV terminal (pH, ORP); input resistance > 5 x 1011 Ω |
Correction variable | Temperature via Pt 100/1000 (pH, chlorine, conductivity) |
Correction range temp. | Chlorine: 41 … 113 °F (5 … 45 °C), pH: 32 … 212 °F (0 … 100 °C), conductivity: 32 … 212 °F (0 … 100 °C) |
Min. current loop | 4 mA |
Max. current loop | 20 mA |
Fault current | 23 mA |
Feed voltage | 2-wire transmitter, 16... 35 V DC, nominal 24 V |
Communication interface | PROFIBUS DP (wall-mounted only) |
Min. ambient temperature | 32 °F (0 °C) |
Max. ambient temperature | 131 °F (55 °C) |
Climate | Relative humidity up to 95% (non-condensing) |
Enclosure rating | IP 65 (wall-mounted, pipe-mounted) |
Display | graphical display |
Housing material | PPE |
Dim. H | 5.31 inch |
Dim. B | 4.92 inch |
D dimension | 2.95 inch |
Weight | 1 | 0.45 lb | kg |
Downloads for DULCOMETER DMT 2-Wire-Transmitters
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
The compact 2-wire transmitter – the link to the PLC and DULCOMETER.
DULCOMETER DMT type transmitters are compact 2-wire transmitters for measured variables The physical variables to be determined by measuring. more in the glossary pH, redox, chlorine, conductive conductivity Conductive conductivity sensors measure the electrolytic conductivity indirectly via ... more in the glossary, temperature.
Easily combined with programmable memory controllers.
Features and Benefits
- Reliable measurement
- High level of operating safety, e.g., probe monitoring (pH), electrical isolation
- Simple flexible installation
- Full text user guidance
- Automatic buffer recognition (pH)
- Auto ranging (conductivity)
- Compact design
- Switch between pH, redox and temperature
Video
Application
Field of application
The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.
- Process control
- Food and beverage industry
- Chemical and pharmaceutical industries
- Water treatment
- Wastewater treatment
- Power plant
Technical Data
Technical Details
Measured Variables:
- pH
- ORP (Redox)
- Chlorine (Free or Total)
- Conductivity (conductive)
- Temperature
Technical Data
Measuring range | pH - 1.00 … 15.00 |
Cell constant | 0.006 … 12.0/cm for conductivity |
Resolution | 0.01 pH |
Accuracy | 0.5% from measurement range |
Measurement input | mV terminal (pH, ORP); input resistance > 5 x 1011 Ω |
Correction variable | Temperature via Pt 100/1000 (pH, chlorine, conductivity) |
Correction range temp. | Chlorine: 41 … 113 °F (5 … 45 °C), pH: 32 … 212 °F (0 … 100 °C), conductivity: 32 … 212 °F (0 … 100 °C) |
Min. current loop | 4 mA |
Max. current loop | 20 mA |
Fault current | 23 mA |
Feed voltage | 2-wire transmitter, 16... 35 V DC, nominal 24 V |
Communication interface | PROFIBUS DP (wall-mounted only) |
Min. ambient temperature | 32 °F (0 °C) |
Max. ambient temperature | 131 °F (55 °C) |
Climate | Relative humidity up to 95% (non-condensing) |
Enclosure rating | IP 65 (wall-mounted, pipe-mounted) |
Display | graphical display |
Housing material | PPE |
Dim. H | 5.31 inch |
Dim. B | 4.92 inch |
D dimension | 2.95 inch |
Weight | 1 | 0.45 lb | kg |
Downloads
Downloads for DULCOMETER DMT 2-Wire-Transmitters
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.