Motor-driven Metering Pump Sigma/ 3 (Basic Type)
Capacity range 45.9 – 264.1 gph (174 - 1,000 l/h), 174 - 58 psi
The patented multi-layer safety diaphragm for excellent process reliability is just one feature of the extremely robust motor-driven metering pump Sigma/3 Basic. It also offers a wide range of power end versions, such as three-phase or 1-phase AC motors, also for use in ATEX areas.
Product description
The robust pump for safe and reliable use
The Sigma/ 3 diaphragm metering pump together with pumps of type Sigma/ 1 and Sigma/ 2 represent an integrated product range. They cover the capacity range from 4.49 - 272.1 gph (17 to 1,030 l/h), with a consistent operating concept, control concept and spare parts management. A wide range of power end versions is available, including some for use in areas at risk from explosion.
Your benefits
Excellent process reliability:
- In the event of an accident, the feed chemical does not escape to the outside nor into the pump's power end, thanks to the patented multi-layer safety diaphragm with optical (optionally electric) signalling
- Integrated relief valve protects the pump against overload
- Reliable operation ensured by bleed option during the suction process
Flexible adaptation to the process:
- The entire Sigma product range is available as standard in a "Physiologically safe in respect of wetted materials" design.
- Metering pumps with electro-polished stainless steel metering head enable them to be used in hygienically challenging applications
- Wide range of power end versions, also for use in areas at risk from explosion, and different flange designs for the use of customised motors
- Customised designs are available on request
Field of application
The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.
- Volume-proportional addition of chemicals in water treatment, e.g. sodium-calcium hypochlorite for the disinfection of potable water
- Addition of chemicals depending on the measured value, e.g. metering of acid and alkali for pH neutralisation in waste water treatment
- Time-controlled addition of chemicals in the cooling water circuit
- Pulse-controlled metering in the bottling of different volumes e.g. glycerin filling of manometers
Technical Details
- Stroke length: 6 mm,
- Stroke length adjustment range: 0 – 100%
- Stroke length adjustment: manually using self-locking rotary dial in 1% increments (optionally with actuator or control drive)
- With the right, constant conditions, correct installation and calibration, precision exceeds ±1 %, based on maximum stroke volume.
- Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
- Patented multi-layer safety diaphragm with optical diaphragm rupture display (as option with diaphragm rupture warning system via a contact)
- Integrated hydraulic relief and bleed valve
- A wide range of power end versions are available: Three-phase standard AC motor, 1-phase AC motor, motors for use in Exe and Exde areas and different flange designs for use in customer-specific motors
- For areas at risk from explosion II 2G Ex h IIC T3 Gb X or II 2G Ex h IIC T4 Gb X (optional)
- IP 55 degree of protection
- High-strength fibreglass-reinforced plastic housing with excellent chemical resistance
For reasons of safety, provide suitable overflow devices during installation for all mechanically deflected diaphragm metering pumps.
Technical Data
Type | Pump capacity at max. back pressure with 1800 rpm motor at 60 Hz | Suction lift | Perm. pre-pressure suction side | Connector Suction/Discharge Side | Shipping weight | |||
---|---|---|---|---|---|---|---|---|
Max. stroke rate | ||||||||
S3Ba | gph | l/h | psi | ml/stroke | Strokes/min | ft | m WC | psi | inches | lb | kg |
* Only available for 50 Hz. | ||||||||
** DN32 plate valves with valve spring | ||||||||
120145 PVT | 45.9 | 174 | 145 | 33.7 | 86 | 16 | 5 | 29 | 1 MNPT | 48.5 | 22 |
120145 SST | 45.9 | 174 | 174 | 33.7 | 86 | 16 | 5 | 29 | 1 MNPT | 57.3 | 26 |
120190 PVT | 66.3 | 251 | 145 | 33.7 | 124 | 16 | 5 | 29 | 1 MNPT | 48.5 | 22 |
120190 SST | 66.3 | 251 | 174 | 33.7 | 124 | 16 | 5 | 29 | 1 MNPT | 57.3 | 26 |
120270 PVT | 92.7 | 351 | 145 | 33.8 | 173 | 16 | 5 | 29 | 1 MNPT | 48.5 | 22 |
120270 SST | 92.7 | 351 | 174 | 33.8 | 173 | 16 | 5 | 29 | 1 MNPT | 57.3 | 26 |
120330 PVT * | - | - | 33.8 | - | 16 | 5 | 29 | 1 MNPT | 48.5 | 22 |
120330 SST * | - | - | 33.8 | - | 16 | 5 | 29 | 1 MNPT | 57.3 | 26 |
070410 PVT | 129.9 | 492 | 102 | 95.1 | 86 | 13 | 4 | 15 | 1-1/2 MNPT ** | 52.9 | 24 |
070410 SST | 129.9 | 492 | 102 | 95.1 | 86 | 13 | 4 | 15 | 1-1/2 MNPT ** | 63.9 | 29 |
070580 PVT | 183.8 | 696 | 102 | 95.1 | 124 | 13 | 4 | 15 | 1-1/2 MNPT ** | 52.9 | 24 |
070580 SST | 183.8 | 696 | 102 | 95.1 | 124 | 13 | 4 | 15 | 1-1/2 MNPT ** | 63.9 | 29 |
040830 PVT | 264.1 | 1,000 | 58 | 95.1 | 173 | 10 | 3 | 15 | 1-1/2 MNPT ** | 52.9 | 24 |
040830 SST | 264.1 | 1,000 | 58 | 95.1 | 173 | 10 | 3 | 15 | 1-1/2 MNPT ** | 63.9 | 29 |
041030 PVT * | - | - | 95.1 | - | 10 | 3 | 15 | 1-1/2 MNPT ** | 52.9 | 24 |
041030 SST * | - | - | 95.1 | - | 10 | 3 | 15 | 1-1/2 MNPT ** | 63.9 | 29 |
Performance data for TTT, see type PVT
Materials in Contact with the Medium
DN 25 ball valves | DN 32 plate valves | |||||||
---|---|---|---|---|---|---|---|---|
Identity code of material | Seals | Suction / discharge connection on dosing head DN 25 | Valve balls | Valve seats | Suction / discharge connection on dosing head DN 32 | Valve plates/valve springs | Valve seats | Integral relief valve |
* With design “F”, the ball seat is made of PVDF, only for DN 25 ball valves | ||||||||
** The valve spring is coated with CTFE (resistance similar to PTFE) | ||||||||
*** Specifically for areas at risk from explosion | ||||||||
**** DN 25 and DN 32 designed as ball non-return valve | ||||||||
PVT | PTFE | PVDF | Glass | PTFE * | PVDF | Ceramic/Hastelloy C + CTFE ** | PTFE | PVDF/FKM or EPDM |
SST | PTFE | Stainless steel 1.4581 | Stainless steel 1.4404 | PTFE * | Stainless steel 1.4581 | Stainless steel 1.4404/Hastelloy C | PTFE | Stainless steel/FKM or EPDM |
TTT *** | PTFE | PTFE + 25% carbon | Ceramic | PTFE * | PVDF | Ceramic/Hastelloy C + CTFE ** | PTFE | - |
PVF | PTFE | PVDF | Glass | PVDF | - | - | - | - |
SSF | PTFE | Stainless steel 1.4581/1.4404 | Stainless steel 1.4404 | PVDF | - | - | - | - |
SSG | PTFE | Stainless steel 1.4581/1.4404 | Stainless steel 1.4404 | Stainless steel 1.4404 | - | - | - | - |
SSH **** | EPDM or FKM | Stainless steel 1.4435 | Ceramic | Stainless steel 1.4404 | Stainless steel 1.4581 | Ceramic/E-CTFE | Stainless steel 1.4404 | - |
Motor Data
Identity code specification | Power supply | Δ/Y | |||
M | 1-phase AC | 230 V | 50/60 Hz | ||
N | 1-phase AC | 115 V | 60 Hz | ||
S | 3-phase | 230 V/400 V | 50/60 Hz |
Motor data sheets can be requested for more information. Versions 265/460V - 60Hz, special motors or special motor flanges are available on request.
In accordance with the Eco Design Directive 2009/125/EC, motors of less than 0.75 kW and motors designed for operation with variable speed are not subject to the IE3 standard.
Information for use in areas at risk from explosion
Only use pumps with the appropriate labelling in line with the ATEX Directive 2014/34/EC in premises at risk from explosion. Ensure that the explosion group, category and degree of protection specified on the label correspond to or are superior to the conditions prevalent in the intended application.
Downloads for Motor-driven Metering Pump Sigma/ 3 (Basic Type)
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
The robust pump for safe and reliable use
The Sigma/ 3 diaphragm metering pump together with pumps of type Sigma/ 1 and Sigma/ 2 represent an integrated product range. They cover the capacity range from 4.49 - 272.1 gph (17 to 1,030 l/h), with a consistent operating concept, control concept and spare parts management. A wide range of power end versions is available, including some for use in areas at risk from explosion.
Your benefits
Excellent process reliability:
- In the event of an accident, the feed chemical does not escape to the outside nor into the pump's power end, thanks to the patented multi-layer safety diaphragm with optical (optionally electric) signalling
- Integrated relief valve protects the pump against overload
- Reliable operation ensured by bleed option during the suction process
Flexible adaptation to the process:
- The entire Sigma product range is available as standard in a "Physiologically safe in respect of wetted materials" design.
- Metering pumps with electro-polished stainless steel metering head enable them to be used in hygienically challenging applications
- Wide range of power end versions, also for use in areas at risk from explosion, and different flange designs for the use of customised motors
- Customised designs are available on request
Video
Application
Field of application
The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.
- Volume-proportional addition of chemicals in water treatment, e.g. sodium-calcium hypochlorite for the disinfection of potable water
- Addition of chemicals depending on the measured value, e.g. metering of acid and alkali for pH neutralisation in waste water treatment
- Time-controlled addition of chemicals in the cooling water circuit
- Pulse-controlled metering in the bottling of different volumes e.g. glycerin filling of manometers
Technical Data
Technical Details
- Stroke length: 6 mm,
- Stroke length adjustment range: 0 – 100%
- Stroke length adjustment: manually using self-locking rotary dial in 1% increments (optionally with actuator or control drive)
- With the right, constant conditions, correct installation and calibration, precision exceeds ±1 %, based on maximum stroke volume.
- Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
- Patented multi-layer safety diaphragm with optical diaphragm rupture display (as option with diaphragm rupture warning system via a contact)
- Integrated hydraulic relief and bleed valve
- A wide range of power end versions are available: Three-phase standard AC motor, 1-phase AC motor, motors for use in Exe and Exde areas and different flange designs for use in customer-specific motors
- For areas at risk from explosion II 2G Ex h IIC T3 Gb X or II 2G Ex h IIC T4 Gb X (optional)
- IP 55 degree of protection
- High-strength fibreglass-reinforced plastic housing with excellent chemical resistance
For reasons of safety, provide suitable overflow devices during installation for all mechanically deflected diaphragm metering pumps.
Technical Data
Type | Pump capacity at max. back pressure with 1800 rpm motor at 60 Hz | Suction lift | Perm. pre-pressure suction side | Connector Suction/Discharge Side | Shipping weight | |||
---|---|---|---|---|---|---|---|---|
Max. stroke rate | ||||||||
S3Ba | gph | l/h | psi | ml/stroke | Strokes/min | ft | m WC | psi | inches | lb | kg |
* Only available for 50 Hz. | ||||||||
** DN32 plate valves with valve spring | ||||||||
120145 PVT | 45.9 | 174 | 145 | 33.7 | 86 | 16 | 5 | 29 | 1 MNPT | 48.5 | 22 |
120145 SST | 45.9 | 174 | 174 | 33.7 | 86 | 16 | 5 | 29 | 1 MNPT | 57.3 | 26 |
120190 PVT | 66.3 | 251 | 145 | 33.7 | 124 | 16 | 5 | 29 | 1 MNPT | 48.5 | 22 |
120190 SST | 66.3 | 251 | 174 | 33.7 | 124 | 16 | 5 | 29 | 1 MNPT | 57.3 | 26 |
120270 PVT | 92.7 | 351 | 145 | 33.8 | 173 | 16 | 5 | 29 | 1 MNPT | 48.5 | 22 |
120270 SST | 92.7 | 351 | 174 | 33.8 | 173 | 16 | 5 | 29 | 1 MNPT | 57.3 | 26 |
120330 PVT * | - | - | 33.8 | - | 16 | 5 | 29 | 1 MNPT | 48.5 | 22 |
120330 SST * | - | - | 33.8 | - | 16 | 5 | 29 | 1 MNPT | 57.3 | 26 |
070410 PVT | 129.9 | 492 | 102 | 95.1 | 86 | 13 | 4 | 15 | 1-1/2 MNPT ** | 52.9 | 24 |
070410 SST | 129.9 | 492 | 102 | 95.1 | 86 | 13 | 4 | 15 | 1-1/2 MNPT ** | 63.9 | 29 |
070580 PVT | 183.8 | 696 | 102 | 95.1 | 124 | 13 | 4 | 15 | 1-1/2 MNPT ** | 52.9 | 24 |
070580 SST | 183.8 | 696 | 102 | 95.1 | 124 | 13 | 4 | 15 | 1-1/2 MNPT ** | 63.9 | 29 |
040830 PVT | 264.1 | 1,000 | 58 | 95.1 | 173 | 10 | 3 | 15 | 1-1/2 MNPT ** | 52.9 | 24 |
040830 SST | 264.1 | 1,000 | 58 | 95.1 | 173 | 10 | 3 | 15 | 1-1/2 MNPT ** | 63.9 | 29 |
041030 PVT * | - | - | 95.1 | - | 10 | 3 | 15 | 1-1/2 MNPT ** | 52.9 | 24 |
041030 SST * | - | - | 95.1 | - | 10 | 3 | 15 | 1-1/2 MNPT ** | 63.9 | 29 |
Performance data for TTT, see type PVT
Materials in Contact with the Medium
DN 25 ball valves | DN 32 plate valves | |||||||
---|---|---|---|---|---|---|---|---|
Identity code of material | Seals | Suction / discharge connection on dosing head DN 25 | Valve balls | Valve seats | Suction / discharge connection on dosing head DN 32 | Valve plates/valve springs | Valve seats | Integral relief valve |
* With design “F”, the ball seat is made of PVDF, only for DN 25 ball valves | ||||||||
** The valve spring is coated with CTFE (resistance similar to PTFE) | ||||||||
*** Specifically for areas at risk from explosion | ||||||||
**** DN 25 and DN 32 designed as ball non-return valve | ||||||||
PVT | PTFE | PVDF | Glass | PTFE * | PVDF | Ceramic/Hastelloy C + CTFE ** | PTFE | PVDF/FKM or EPDM |
SST | PTFE | Stainless steel 1.4581 | Stainless steel 1.4404 | PTFE * | Stainless steel 1.4581 | Stainless steel 1.4404/Hastelloy C | PTFE | Stainless steel/FKM or EPDM |
TTT *** | PTFE | PTFE + 25% carbon | Ceramic | PTFE * | PVDF | Ceramic/Hastelloy C + CTFE ** | PTFE | - |
PVF | PTFE | PVDF | Glass | PVDF | - | - | - | - |
SSF | PTFE | Stainless steel 1.4581/1.4404 | Stainless steel 1.4404 | PVDF | - | - | - | - |
SSG | PTFE | Stainless steel 1.4581/1.4404 | Stainless steel 1.4404 | Stainless steel 1.4404 | - | - | - | - |
SSH **** | EPDM or FKM | Stainless steel 1.4435 | Ceramic | Stainless steel 1.4404 | Stainless steel 1.4581 | Ceramic/E-CTFE | Stainless steel 1.4404 | - |
Motor Data
Identity code specification | Power supply | Δ/Y | |||
M | 1-phase AC | 230 V | 50/60 Hz | ||
N | 1-phase AC | 115 V | 60 Hz | ||
S | 3-phase | 230 V/400 V | 50/60 Hz |
Motor data sheets can be requested for more information. Versions 265/460V - 60Hz, special motors or special motor flanges are available on request.
In accordance with the Eco Design Directive 2009/125/EC, motors of less than 0.75 kW and motors designed for operation with variable speed are not subject to the IE3 standard.
Information for use in areas at risk from explosion
Only use pumps with the appropriate labelling in line with the ATEX Directive 2014/34/EC in premises at risk from explosion. Ensure that the explosion group, category and degree of protection specified on the label correspond to or are superior to the conditions prevalent in the intended application.