gamma/ X Solenoid Diaphragm Metering Pump
0.61 to 11.89 gph (2.3 to 45 l/h) at pressures up to 363 psi
The solenoid-driven diaphragm metering pump gamma incorporates a wealth of eXcellent ingenuity! With integrated pressure measurement, it ensures the smooth running of your metering process. The gamma/ X is ideal for all metering work involving liquid media.
Product description
X-tremely clever!
The new gamma/ X is the first metering pump with predictive intelligence. Thanks to its controlled solenoid drive with sensor-free pressure measurement, it detects hydraulic faults even in the case of minimal deviations – immediately and optimally matching its output to the pressure conditions and properties of the medium while protecting the pump and piping systems from overload situations.
Your benefits
- Simple adjustment of the capacity directly in GPH
- Configurable discharge stroke, continuous or pulsed dosing
- Configurable suction stroke duration
- Suitable for continuous micro-metering from 1 ml/hr thanks to the innovative solenoid control
- Integrated pressure measurement allows for detection of blocked discharge line, broken discharge lines and air or gas bubbles trapped in the dosing head
- Acrylic/PVC, PVT (PVDF) and Stainless-Steel liquid end material versions
- Auto degassing liquid ends in Acrylic/ PVC and PVT
- High viscosity liquid ends (PVT4) for viscosities of up to 3000 cP
- Large backlit graphic display and status LEDs with 360° visibility
- External control via voltage-free contacts with pulse multiplier/divider function
- Standard internal programmable timer for real-time dependent dosing routines i.e., biocides, cooling towers etc.
- Standard pump capable of accepting 2-stage tank level sensor input, flow monitor input, diaphragm rupture sensor input and control cable input
Field of application
The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.
- Can be integrated into automated processes and used in all industries.
- The pump can work as a control unit with the timer, for example in cooling water treatment.
Technical Details
- Stroke rate adjustable from 1 – 12,000 strokes per hour
- Electronic stroke length adjustment, continuous from 0 - 100% (recommended range 30 - 100%)
- External control via standard 4-20 mA signal, and scalable adjustment of mA signal to stroke rate
- NSF/ANSI 61 Approved Liquid ends
- Bluetooth, PROFIBUS®, CANbus interface as an optional feature
- Standard pump capable of accepting 2-stage tank level sensor input, flow monitor input, diaphragm rupture sensor input and control cable input
Technical Data
Pump type | Capacity at max. back pressure | Stroke rate | Connector size | Suction lift* | Shipping weight | |||
---|---|---|---|---|---|---|---|---|
PP, NP, PV, TT | SS | |||||||
psi | gph | l/h | ml/stroke | Strokes/min | inch | ft | m WC | lb | kg | lb | kg | |
* Suction lift with a filled dosing head and filled suction line, with a self-bleeding dosing head with air in the suction line. | ||||||||
** 363 psi variant only available with dosing head material NP or SS | ||||||||
*** With stainless steel design, 6 mm connector width. | ||||||||
**** With stainless steel design, 12 mm connector width. | ||||||||
***** With stainless steel design DN 10. | ||||||||
Metering pumps with non-self-bleeding dosing head | ||||||||
GMXa 1602 | 232 | 0.61 | 2.3 | 0.19 | 200 | 1/4 x 3/16 | 20 | 6.0 | 7.9 | 3.6 | 9 | 4.1 |
GMXa 1604 | 232 | 0.95 | 3.6 | 0.30 | 200 | 1/4 x 3/16 | 16 | 5.0 | 7.9 | 3.6 | 9 | 4.1 |
GMXa 2504 | 363 ** | 1 | 3.8 | 0.32 | 200 | 8 x 4 mm *** | 13 | 4.0 | 10.8 | 4.9 | 12.1 | 5.5 |
GMXa 0708 | 102 | 2.01 | 7.6 | 0.63 | 200 | 1/2 x 3/8 | 13 | 4.0 | 8.2 | 3.7 | 11 | 5.0 |
GMXa 1009 | 145 | 2.38 | 9.0 | 0.75 | 200 | 1/2 x 3/8 | 10 | 3.0 | 11.2 | 5.1 | 14.3 | 6.5 |
GMXa 0414 | 58 | 3.57 | 13.5 | 1.13 | 200 | 1/2 x 3/8 **** | 10 | 3.0 | 8.2 | 3.7 | 11 | 5.0 |
GMXa 0715 | 102 | 3.83 | 14.5 | 1.21 | 200 | 1/2 x 3/8 **** | 10 | 3.0 | 11.2 | 5.1 | 14.3 | 6.5 |
GMXa 0220 | 29 | 5.2 | 19.7 | 1.64 | 200 | 1/2 x 3/8 | 7 | 2.0 | 8.2 | 3.7 | 11 | 5.0 |
GMXa 0424 | 58 | 6.34 | 24.0 | 2.00 | 200 | 1/2 x 3/8 | 10 | 3.0 | 11.2 | 5.1 | 14.3 | 6.5 |
GMXa 0245 | 29 | 11.89 | 45.0 | 3.70 | 200 | 1/2 x 3/8 ***** | 7 | 2.0 | 11.5 | 5.2 | 15.4 | 7.0 |
Metering pumps with self-degassing dosing head (dosing head design 7) | ||||||||
GMXa 1604 | 145 | 0.58 | 2.2 | 0.18 | 200 | 1/4 x 3/16 | 6 | 1.8 | 7.9 | 3.6 | - |
GMXa 0708 | 102 | 1.48 | 5.6 | 0.47 | 200 | 1/2 x 3/8 | 6 | 1.8 | 8.2 | 3.7 | - |
GMXa 1009 | 145 | 1.74 | 6.6 | 0.55 | 200 | 1/2 x 3/8 | 6 | 1.8 | 11.2 | 5.1 | - |
GMXa 0414 | 58 | 3.22 | 12.2 | 1.01 | 200 | 1/2 x 3/8 | 6 | 1.8 | 8.2 | 3.7 | - |
GMXa 0715 | 102 | 3.43 | 13.0 | 1.08 | 200 | 1/2 x 3/8 | 6 | 1.8 | 11.2 | 5.1 | - |
GMXa 0220 | 29 | 4.76 | 18.0 | 1.50 | 200 | 1/2 x 3/8 | 6 | 1.8 | 8.2 | 3.7 | - |
GMXa 0424 | 58 | 5.81 | 22.0 | 1.83 | 200 | 1/2 x 3/8 | 6 | 1.8 | 11.2 | 5.1 | - |
GMXa 0245 | 29 | 10.57 | 40.0 | 3.33 | 200 | 1/2 x 3/8 | 6 | 1.8 | 11.5 | 5.2 | - |
gamma/ X metering pumps with dosing heads for higher-viscosity media have a 10 – 20 % lower capacity and are not self-priming with all feed chemicals. G 3/4-DN 10 connector with d 16-DN 10 hose nozzle.
The vPTFE diaphragm is limited to a maximum operating pressure of 10 bar. The pump capacities of the metering pumps with vPTFE diaphragm may be 10-20 % lower than those with a standard diaphragm.
All data calculated with water at 68 °F (20 °C).
Materials in Contact with the Medium
Identity code of material | Dosing head | Connection on suction/discharge side | Ball seat | Seals | Balls |
---|---|---|---|---|---|
PVT | PVDF | PVDF | PVDF | PTFE | Ceramic |
PPT | Polypropylene | PVDF | PVDF | PTFE | Ceramic |
PPE | Polypropylene | Polypropylene | EPDM | EPDM | Ceramic |
PPB | Polypropylene | Polypropylene | FKM A | FKM A | Ceramic |
NPT | Clear acrylic | PVDF | PVDF | PTFE | Ceramic |
NPE | Clear acrylic | PVC | EPDM | EPDM | Ceramic |
NPB | Clear acrylic | PVC | FKM A | FKM A | Ceramic |
SST | Stainless steel 1.4404 | Stainless steel 1.4404 | Ceramic | PTFE | Ceramic |
TTT | Carbon-filled PTFE | Carbon-filled PTFE | Ceramic | PTFE | Ceramic |
Metering reproducibility: ±1% when used according to the instructions in the operating instructions
Permissible ambient temperature: 14 °F to 113 °F (-10 °C to +45 °C)
Mean power consumption: 25/30 W
Degree of protection: IP 66, NEMA 4X, insulation class F
Scope of supply
Metering pump with mains cable, connector kit for hose/tube connector as per table.
Downloads for gamma/ X Solenoid Diaphragm Metering Pump
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
X-tremely clever!
The new gamma/ X is the first metering pump with predictive intelligence. Thanks to its controlled solenoid drive with sensor-free pressure measurement, it detects hydraulic faults even in the case of minimal deviations – immediately and optimally matching its output to the pressure conditions and properties of the medium while protecting the pump and piping systems from overload situations.
Your benefits
- Simple adjustment of the capacity directly in GPH
- Configurable discharge stroke, continuous or pulsed dosing
- Configurable suction stroke duration
- Suitable for continuous micro-metering from 1 ml/hr thanks to the innovative solenoid control
- Integrated pressure measurement allows for detection of blocked discharge line, broken discharge lines and air or gas bubbles trapped in the dosing head
- Acrylic/PVC, PVT (PVDF) and Stainless-Steel liquid end material versions
- Auto degassing liquid ends in Acrylic/ PVC and PVT
- High viscosity liquid ends (PVT4) for viscosities of up to 3000 cP
- Large backlit graphic display and status LEDs with 360° visibility
- External control via voltage-free contacts with pulse multiplier/divider function
- Standard internal programmable timer for real-time dependent dosing routines i.e., biocides, cooling towers etc.
- Standard pump capable of accepting 2-stage tank level sensor input, flow monitor input, diaphragm rupture sensor input and control cable input
Video
Application
Field of application
The following list is a general representation of basically suitable applications for this product. Please contact your personal representative to discuss the use of the product in your individual application.
- Can be integrated into automated processes and used in all industries.
- The pump can work as a control unit with the timer, for example in cooling water treatment.
Technical Data
Technical Details
- Stroke rate adjustable from 1 – 12,000 strokes per hour
- Electronic stroke length adjustment, continuous from 0 - 100% (recommended range 30 - 100%)
- External control via standard 4-20 mA signal, and scalable adjustment of mA signal to stroke rate
- NSF/ANSI 61 Approved Liquid ends
- Bluetooth, PROFIBUS®, CANbus interface as an optional feature
- Standard pump capable of accepting 2-stage tank level sensor input, flow monitor input, diaphragm rupture sensor input and control cable input
Technical Data
Pump type | Capacity at max. back pressure | Stroke rate | Connector size | Suction lift* | Shipping weight | |||
---|---|---|---|---|---|---|---|---|
PP, NP, PV, TT | SS | |||||||
psi | gph | l/h | ml/stroke | Strokes/min | inch | ft | m WC | lb | kg | lb | kg | |
* Suction lift with a filled dosing head and filled suction line, with a self-bleeding dosing head with air in the suction line. | ||||||||
** 363 psi variant only available with dosing head material NP or SS | ||||||||
*** With stainless steel design, 6 mm connector width. | ||||||||
**** With stainless steel design, 12 mm connector width. | ||||||||
***** With stainless steel design DN 10. | ||||||||
Metering pumps with non-self-bleeding dosing head | ||||||||
GMXa 1602 | 232 | 0.61 | 2.3 | 0.19 | 200 | 1/4 x 3/16 | 20 | 6.0 | 7.9 | 3.6 | 9 | 4.1 |
GMXa 1604 | 232 | 0.95 | 3.6 | 0.30 | 200 | 1/4 x 3/16 | 16 | 5.0 | 7.9 | 3.6 | 9 | 4.1 |
GMXa 2504 | 363 ** | 1 | 3.8 | 0.32 | 200 | 8 x 4 mm *** | 13 | 4.0 | 10.8 | 4.9 | 12.1 | 5.5 |
GMXa 0708 | 102 | 2.01 | 7.6 | 0.63 | 200 | 1/2 x 3/8 | 13 | 4.0 | 8.2 | 3.7 | 11 | 5.0 |
GMXa 1009 | 145 | 2.38 | 9.0 | 0.75 | 200 | 1/2 x 3/8 | 10 | 3.0 | 11.2 | 5.1 | 14.3 | 6.5 |
GMXa 0414 | 58 | 3.57 | 13.5 | 1.13 | 200 | 1/2 x 3/8 **** | 10 | 3.0 | 8.2 | 3.7 | 11 | 5.0 |
GMXa 0715 | 102 | 3.83 | 14.5 | 1.21 | 200 | 1/2 x 3/8 **** | 10 | 3.0 | 11.2 | 5.1 | 14.3 | 6.5 |
GMXa 0220 | 29 | 5.2 | 19.7 | 1.64 | 200 | 1/2 x 3/8 | 7 | 2.0 | 8.2 | 3.7 | 11 | 5.0 |
GMXa 0424 | 58 | 6.34 | 24.0 | 2.00 | 200 | 1/2 x 3/8 | 10 | 3.0 | 11.2 | 5.1 | 14.3 | 6.5 |
GMXa 0245 | 29 | 11.89 | 45.0 | 3.70 | 200 | 1/2 x 3/8 ***** | 7 | 2.0 | 11.5 | 5.2 | 15.4 | 7.0 |
Metering pumps with self-degassing dosing head (dosing head design 7) | ||||||||
GMXa 1604 | 145 | 0.58 | 2.2 | 0.18 | 200 | 1/4 x 3/16 | 6 | 1.8 | 7.9 | 3.6 | - |
GMXa 0708 | 102 | 1.48 | 5.6 | 0.47 | 200 | 1/2 x 3/8 | 6 | 1.8 | 8.2 | 3.7 | - |
GMXa 1009 | 145 | 1.74 | 6.6 | 0.55 | 200 | 1/2 x 3/8 | 6 | 1.8 | 11.2 | 5.1 | - |
GMXa 0414 | 58 | 3.22 | 12.2 | 1.01 | 200 | 1/2 x 3/8 | 6 | 1.8 | 8.2 | 3.7 | - |
GMXa 0715 | 102 | 3.43 | 13.0 | 1.08 | 200 | 1/2 x 3/8 | 6 | 1.8 | 11.2 | 5.1 | - |
GMXa 0220 | 29 | 4.76 | 18.0 | 1.50 | 200 | 1/2 x 3/8 | 6 | 1.8 | 8.2 | 3.7 | - |
GMXa 0424 | 58 | 5.81 | 22.0 | 1.83 | 200 | 1/2 x 3/8 | 6 | 1.8 | 11.2 | 5.1 | - |
GMXa 0245 | 29 | 10.57 | 40.0 | 3.33 | 200 | 1/2 x 3/8 | 6 | 1.8 | 11.5 | 5.2 | - |
gamma/ X metering pumps with dosing heads for higher-viscosity media have a 10 – 20 % lower capacity and are not self-priming with all feed chemicals. G 3/4-DN 10 connector with d 16-DN 10 hose nozzle.
The vPTFE diaphragm is limited to a maximum operating pressure of 10 bar. The pump capacities of the metering pumps with vPTFE diaphragm may be 10-20 % lower than those with a standard diaphragm.
All data calculated with water at 68 °F (20 °C).
Materials in Contact with the Medium
Identity code of material | Dosing head | Connection on suction/discharge side | Ball seat | Seals | Balls |
---|---|---|---|---|---|
PVT | PVDF | PVDF | PVDF | PTFE | Ceramic |
PPT | Polypropylene | PVDF | PVDF | PTFE | Ceramic |
PPE | Polypropylene | Polypropylene | EPDM | EPDM | Ceramic |
PPB | Polypropylene | Polypropylene | FKM A | FKM A | Ceramic |
NPT | Clear acrylic | PVDF | PVDF | PTFE | Ceramic |
NPE | Clear acrylic | PVC | EPDM | EPDM | Ceramic |
NPB | Clear acrylic | PVC | FKM A | FKM A | Ceramic |
SST | Stainless steel 1.4404 | Stainless steel 1.4404 | Ceramic | PTFE | Ceramic |
TTT | Carbon-filled PTFE | Carbon-filled PTFE | Ceramic | PTFE | Ceramic |
Metering reproducibility: ±1% when used according to the instructions in the operating instructions
Permissible ambient temperature: 14 °F to 113 °F (-10 °C to +45 °C)
Mean power consumption: 25/30 W
Degree of protection: IP 66, NEMA 4X, insulation class F
Scope of supply
Metering pump with mains cable, connector kit for hose/tube connector as per table.
Downloads
Downloads for gamma/ X Solenoid Diaphragm Metering Pump
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.